PREPARE HOOD LOCATION

ROOF CAP
SOFFIT
CABINET
HOOD
HOOD
24" - 30" ABOVE
COOKING SURFACE
1
Determine whether hood will discharge vertically (3¼" x 10"),
or horizontally (3¼" x 10" only). For vertical or horizontal dis-
charge, run ductwork between the hood location and a roof
cap or wall cap. For best results, use a minimum number of
transitons and elbows.
2
Use diagrams, below, for proper placement of ductwork and
electrical cutout in cabinet or wall. For a non-ducted installa-
tion, DO NOT cut a duct access hole.
HOOD MOUNTING SCREWS (4)
15 /
13
"
(30" hood)
16
15 /
16
"
(36" hood)
16
15 /
19
"
16
(42" hood)
CABINET FRONT
CABINET BOTTOM
5¼"
VERTICAL DUCT
ACCESS HOLE
5"
1¼"
WOOD SHIMS
CENTER
(recessed-bottom
cabinets only)
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
HORIZONTAL DUCT
3¾"
CABINET
BOTTOM
5¼"
13
15 / 16
"
(30" hood)
16
15 / 16
"
(36" hood)
19
15 / 16
"
(42" hood)
HOOD
MOUNTING
SCREWS (4)
3
Run house wiring between service panel and hood location.
3¼" X 10"
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
WALL CAP
3¼" X 10" DUCT
(For horizontal discharge)
3¼" X 10"
VERTICAL DUCTING
15 /
13
"
16
(30" hood)
15 /
16
"
16
(36" hood)
15 /
19
"
(42" hood)
16
7½"
5¼"
2"
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
LINE
3¼" X 10"
HORIZONTAL DUCTING
1 / 8
"
¾"
ACCESS HOLE
5¼"
7½"
13
15 / 16
"
(30" hood)
16
15 / 16
"
(36" hood)
19
15 / 16
"
(42" hood)
ELECTRICAL
CENTER
ACCESS HOLE
LINE
(in wall)

PREPARE THE HOOD

FILTERS
1
Remove tape holding Filters in place. Pull down on filter
tabs or finger holes and lift filters out. Set filters aside.
®
TEFLON
-
COATED
BOTTOM
COVER
(Held in
place with
2 screws)
2
Remove Teflon
cover and mounting screws aside.
10½"
Teflon
®
is a registered trademark of DuPont.
1½"
3
Remove Damper/Duct Connector from inside the hood.
Set connector aside - with mounting screws and parts bag.
ALLURE
®
RANGE HOOD
®
-coated bottom cover from hood. Set
QS2 SERIES
Page 2
DAMPER/
DUCT
CONNECTOR