Minimum Clearance To Combustibles; Floor Protection - Masport F2401M Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

IMPORTANT
Use only the instructions and clearance dimensions on this page for
heaters to be installed in Australia and New Zealand.
The Masport F2400M has been tested by the AHHA Testing Laboratory
and conforms to AS/NZS 2918:200, Report No. ATL19-04.
AUSTRALIA ONLY
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as the clearance depend on whether the airmate
or the rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
Residential Installation Clearances to Combustible Walls
Unit
Medium F2400M with Rear Deflector*
Australia
Rear firebox shield extension fitted, and full length half perforated decromesh flue surround or 900mm long
half round enamelled mild steel flue shield fitted.
New Zealand
Rear firebox shield extension fitted, and full length stainless steel shield with heat dispersal cap fitted to
flue shield top.
Flue systems tested:
Acorn Special Insulated
FLOMET Super Single
Shamic 1A
Masport (NZ)
Floor Protector:
6mm thick fibre cement sheet underneath heater extending 300mm in front and 200mm from the sides of the firebox
opening.
Masport Freestanding Woodstove
AUSTRALIA & NEW ZEALAND ONLY
From Unit
A
450mm
The Masport F2400M has been tested with the flue kits listed
below. A default flue kit as listed in AS/NZS 2918:2001 may also
be used.
These are the only flue kits certified for use with this heater for
installation in Australia and New Zealand.
From Corner
B
C
150mm
225mm
755mm
INSTALLATION
From Flue Center-Line
D
E
315mm
F
555mm
5