Omron Intelli Sense BP760CAN Instruction Manual
Omron Intelli Sense BP760CAN Instruction Manual

Omron Intelli Sense BP760CAN Instruction Manual

7 series with comfit cuff

Advertisement

INSTRUCTION MANUAL
7 series
Blood Pressure Monitor
with ComFit
TM
Cuff
BP760CAN
Model

Advertisement

Table of Contents
loading

Summary of Contents for Omron Intelli Sense BP760CAN

  • Page 1 INSTRUCTION MANUAL 7 series Blood Pressure Monitor with ComFit Cuff BP760CAN Model...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Before Using the Monitor Introduction ..........4 Safety Information .
  • Page 3 TABLE OF CONTENTS Taking a Measurement .........27 Cuff Wrap Guide .
  • Page 4: Before Using The Monitor

    • Storage Case • Instruction Manual printed in English and French • Quick Start Guide The BP760CAN 7 series Automatic Blood Pressure Monitor is intended for home use. Please read this instruction manual thoroughly before using the unit. Please keep for future reference.
  • Page 5: Safety Information

    SAFETY INFORMATION INTENDED USE This product is designed to measure the blood pressure and pulse rate of people within the range of the designated arm cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the “Safety Information”...
  • Page 6 Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Use only 1.5V alkaline batteries with this device.
  • Page 7: Risk Of Electrical Shock

    Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the...
  • Page 8: Before Taking A Measurement

    BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement. 2.
  • Page 9: Operating Instructions

    Operating Instructions KNOW YOUR UNIT Main Unit: Display SET Button Morning/Evening Average ) Button Memory ( ) Button Up/Down Start/Stop Button ) Buttons Battery Compartment Air Jack AC Adapter Jack...
  • Page 10 KNOW YOUR UNIT Components: Housing Air Tube Cord AC Adapter Air Plug (Connects to Air Jack) Arm Cuff INSTRUCTION MANUAL 7 series Blood Pressure Monitor with ComFit Cuff BP760CAN Model Instruction Manual Storage Case Quick Start Guide...
  • Page 11: Unit Display

    UNIT DISPLAY Morning Average Symbol Evening Average Symbol Date/Time Display Irregular Heartbeat Symbol Average Value Symbol Week Display Memory Symbol Systolic Blood Pressure Morning Hypertension Symbol Movement Symbol Blood Pressure Level Indicator Diastolic Blood Pressure Deflation Symbol Heartbeat Symbol Cuff Wrap Guide Low Battery Indicator Pulse Display / Memory Number...
  • Page 12: Display Symbols

    DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. Normal Heartbeat An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from Pulse the average rhythm or 25% more than the...
  • Page 13: Morning Hypertension Symbol

    85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory. Omron Healthcare recommends you contact your physician if the MORNING HYPERTENSION SYMBOL appears on the display with your measurement values.
  • Page 14: Heartbeat Symbol

    DISPLAY SYMBOLS HEARTBEAT SYMBOL ( The Heartbeat symbol flashes on the display at every heartbeat during the measurement. AVERAGE VALUE SYMBOL ( The Average Value Symbol is displayed when you press the memory button. The most recent average reading appears on the display screen. MORNING AVERAGE SYMBOL ( The Morning Average symbol is displayed when viewing Morning Averages using the Memory Function.
  • Page 15: Using The Ac Adapter

    The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position. NOTES: • Use only the authorized Omron AC Adapter that came with this monitor. • We recommend you install the batteries even if the AC Adapter is used.
  • Page 16 USING THE AC ADAPTER TO CONNECT THE AC ADAPTER Insert the AC Adapter Plug into Housing the AC Adapter Jack on the back side of the monitor as illustrated. Plug the AC Adapter into a 120V AC outlet (60 cycles). Cord TO DISCONNECT THE AC ADAPTER Hold the Housing to remove the AC Adapter from the electrical...
  • Page 17: Battery Installation

    BATTERY INSTALLATION Battery Cover 1. Remove the battery cover by pulling the hook up while pushing it in the direction of the arrow. 2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
  • Page 18 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Longlife alkaline batteries are recommended. WARNING If battery fluid should get in your eyes, immediately rinse with plenty of clean water.
  • Page 19: Setting The Date And Time

    SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct.
  • Page 20 SETTING THE DATE AND TIME 1. TO START THE SETTING Press the SET button to adjust the date and time. The year flashes on the display. 2. SETTING THE YEAR The year can be set between 2010 and 2040. When the display reaches 2040, it will return to 2010.
  • Page 21 SETTING THE DATE AND TIME 3. SETTING THE MONTH Press the Up button ( ) to advance by one month. Press the SET button to set the current month. The day flashes on the display. 4. SETTING THE DAY Press the Up button ( ) to advance by one day.
  • Page 22 SETTING THE DATE AND TIME 5. SETTING THE HOUR The time is set using AM or PM. Press the Up button ( ) to advance by one hour. Press the SET button to set the current hour. The minute flashes on the display. 6.
  • Page 23: Applying The Arm Cuff

    APPLYING THE ARM CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
  • Page 24 APPLYING THE ARM CUFF 3. Hold the thumb grip on the cuff Thumb Grip securely with your right hand. Cloth Fastener 4. Turn the palm of your left hand upward. 5. Apply the cuff to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger.
  • Page 25 APPLYING THE ARM CUFF 6. Wrap the cuff firmly in place around your arm using the cloth fastener.
  • Page 26: Applying The Cuff On The Right Arm

    APPLYING THE ARM CUFF APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 5 on page 24. Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm.
  • Page 27: Taking A Measurement

    TAKING A MEASUREMENT The monitor automatically determines your ideal inflation level. In rare circumstances when a higher inflation may be necessary, the monitor automatically re-inflates the cuff up to 30 mmHg higher than the initial inflation and restarts the measurement. WARNING Contact your physician for specific information about your blood pressure.
  • Page 28 TAKING A MEASUREMENT 1. Sit on a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart. 2. Press the START/STOP button. All symbols appear on the display. The cuff starts to inflate automatically.
  • Page 29 TAKING A MEASUREMENT 3. Inflation stops automatically and the measurement is started. As the cuff deflates, decreasing numbers appear on the display. The Heartbeat Symbol ( ) flashes at every heartbeat. 4. When the measurement is complete, the arm cuff completely deflates.
  • Page 30: Special Conditions

    TAKING A MEASUREMENT WARNING The monitor is not intended to be a diagnostic device. SPECIAL CONDITIONS CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied. If your systolic pressure is known to be more than 220 mmHg, press and hold the START/STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure.
  • Page 31: Using The Memory Function

    USING THE MEMORY FUNCTION The monitor is designed to store the blood pressure and the pulse rate in the memory every time a measurement is completed. The monitor automatically stores up to 60 sets of measurement values (blood pressure and pulse rate). When 60 sets of measurement values are stored, the oldest record is deleted to save the most recent values.
  • Page 32: To Display The Measurement Values

    USING THE MEMORY FUNCTION TO DISPLAY THE MEASUREMENT VALUES 1. Press the Memory button ( The Average Symbol ( ) appears on the display when the average reading is shown. 2. Press the Down button ( ) to display the most recent set of measurement values on the screen.
  • Page 33: Morning And Evening Averages

    USING THE MEMORY FUNCTION MORNING AND EVENING AVERAGES The monitor calculates and displays a weekly average for measurements taken in the morning ( ) and evening ( ). The monitor stores 8 weeks of Morning Averages and 8 weeks of Evening Averages. NOTE: The week begins Sunday at 4:00 AM.
  • Page 34: To Display Morning And Evening Averages

    USING THE MEMORY FUNCTION TO DISPLAY MORNING AND EVENING AVERAGES 1. Press the Morning/ Evening Average button ( ) to select the Morning or Evening average. The average for the current week “THIS WEEK” appears on the display. 2. Press the Down ( ) button to display the previous weeks.
  • Page 35: Display Combinations

    USING THE MEMORY FUNCTION DISPLAY COMBINATIONS In addition to the Morning Average and Evening Average Symbols, the monitor may also display the Morning Hypertension Symbol if the morning average for that week is above the internationally recognized guidelines. (See page 13 for details.) Depending on your measurement results, these may be displayed in the following combinations.
  • Page 36: To Delete All Values Stored In The Memory

    USING THE MEMORY FUNCTION The Morning Hypertension Symbol appears if the weekly average for morning measurements is above 135/85. In this case the Morning Hypertension Symbol is displayed when the Evening Average is displayed, regardless of the values for the Evening Average.
  • Page 37: Care And Maintenance

    Care and Maintenance CARE AND MAINTENANCE To keep your blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Keep the monitor in the storage case when not in use. Make sure the AC adapter is placed under the main unit so that it does not damage the display.
  • Page 38 CARE AND MAINTENANCE Use the unit consistent with the instruction provided in this manual. CAUTION Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components. CAUTION Use only Omron authorized parts and accessories.
  • Page 39: Error Indicators And Troubleshooting Tips

    ERROR INDICATORS AND TROUBLESHOOTING TIPS ERROR INDICATORS SYMBOL CAUSE CORRECTION Insert the plug securely. Refer to “Applying the Air plug disconnected. Arm Cuff”. Apply the arm cuff correctly. Refer to “Applying Arm cuff not applied correctly. the Arm Cuff”. Air is leaking from the arm cuff. Replace the cuff with the new one.
  • Page 40 ERROR INDICATORS AND TROUBLESHOOTING TIPS TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. Replace all four batteries with new ones. No display appears on the unit. Check the battery installation for proper placement of the battery polarities. Blood pressure varies constantly. Many factors including stress, time of day, and how you wrap the cuff, Measurement values appear...
  • Page 41: Fcc Statement

    FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 42: Limited Warranty

    AND OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY. OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES.
  • Page 43: Specifications

    SPECIFICATIONS Model: BP760CAN (HEM-7220-CA) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve...
  • Page 44 Made in China Omron Healthcare, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www.omronhealthcare.ca Copyright © 2010 Omron Healthcare, Inc.

Table of Contents