MaInTenanCe

during Heating season

1. Establish a daily routine for storage of fuel and care of
the furnace. Check frequently for crusted ash buildup
until experience shows how often cleaning is necessary.
Be aware that the hotter the fire, the less creosote, and
that weekly cleanings may be necessary in mild weather,
even though monthly cleanings may be enough in the
coldest months. Have a clearly understood plan in place
in the event of a chimney fire.
2. The secondary burn chamber must be cleaned out
weekly as necessary. Ensure that the ash clean out
door is securely closed after each cleaning.
Place ashes in a steel container with a tightly fitting lid.
Other waste should not be placed in the container with
the ashes.
3. Check the water level daily, ensure the level is well
above the "ADD" mark.
Oxygen buildup causes corrosion inside the water system.
Keeping the water reservoir completely full prevents
oxygen buildup, especially during the summer months
when the furnace is not in use.
4. Check the door and lid gaskets to ensure an air tight fit.
Adjust hinges and latch as needed.
5. Check and clean the heat exchanger flues weekly. A
buildup in the flues and chimney will cause a poor draft
and reduce efficiency.
6. Check and clean the air passages in the upper loading
door frame several times during the heating season. To
clean the air passages, remove the air pan.
To remove the air pan, swing the smoke curtain into the
horizontal position and pull the air pan lock forward. See
Figure 1. Drop the air pan down and pull forward, removing
the air pan with the smoke curtain.
Inspect and clean the two rectangular air passages on
the upper door frame as well as removing any buildup on
the air pan. Move Run/Load lever to expose air passages.
Move the Exhaust Exit lever back and forth to ensure easy
movement.
To reinstall, guide the air pan into the slots on either side of
the door frame. See Figure 1. Push in and up, and secure
in place by pushing the air pan lock back into the lock
position.
7. Cover plates and guards must be in place at all times,
except during maintenance and servicing.
8. Rear access door must be secured with latch lock bolt.
See page 9. Tighten with a wrench.
9. All doors must be closed during operation.
10. Operate the backup heating system (gas, oil or electric)
periodically to ensure that it will operate satisfactorily
when needed.
20
air pan
air pan
mounting notches
smoke
Curtain
Figure 1
2 air
passages
Clean Out
Cover
Figure 2
Empyre Elite Xt
100
Figure 3
EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual
air pan
lock

Advertisement