Forced Operation; Trial Operation - LG LS-J0762YL/NM/NN/NQ Service Manual

Room air conditioner
Table of Contents

Advertisement

12. Auto restarting operation
• When the power is restarted after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• Operation mode that is kept on the memory
- State of operation ON/OFF
- Operation mode/setting temp./selected airflow speed
- Sleep timer mode/remaining time of sleep timer
- Chaos Swing

13. Forced operation

• To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
• The operation condition is set according to the outdoor temp. and intake air temperature as follows.
Outdoor temp.
over 24°C
21~24°C
18~21°C
below 18°C
The unit select before operating mode in 3 hours.

14. Trial Operation

• Press the Tact Switch for compulsory operation of the main body for 3 seconds in order to operate in the trial
operation mode.
- Operation mode: Cold
- Indoor pan: Strong wind
- COMP frequency: Step 5
- COMP compulsorily operates for about 18 minutes irrespective of indoor temperature.
Operating Mode
Cooling
Healthy Dehumidification
Intake air temp. ≥ 25°C
Intake air temp. < 25°C
Heating
Dehumidification
Heating
-21-
Setting speed of
Setting temp.
indoor fan
22°C
23°C
High speed
23°C
24°C
24°C