Neutro Wood pellet boiler Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.
Dear Customer First of all we would like to thank you for the trust you have placed in us when purchasing one of our products. We have prepared this short manual for you in an attempt to make it as easy as possible for you to use our product. We also advise you to show the specific technical information given on the following pages to those in charge of assembling the unit and making the product operational so that these operations can be carried out as correctly as possible. LIST OF CONTENTS Chapter 1 Introduction ...
Page 3
These instructions cover the basic principles to ensure the satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove. It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303, BS 6461 and EN 12391‐1 (replacing BS 7566 which has been withdrawn) as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J. Please note that it is a legal requirement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme. HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www.hetas.co.uk. PREAMBLE We would like to help you understand our manual by listing briefly the meaning of the symbols characterising the most important and significant information given: Warnings and safety Important information The manufacturer declines any liability for any damage caused to people or property because of failure to observe the simple rules of installation and use, described in this manual. You are also reminded that in installing the product you must observe relevant national and local building regulations. ...
1. INTRODUCTION 1.1 PRODUCT SIZE AND CONSTRUCTION FEATURES We show below the main dimensions of the pellet heater. Typical Dimensions Height 1015 mm Width 580 mm Depth 585 mm Weight 230 kg Fume outlet diameter 80 mm ...
1.2 PRODUCT TECHNICAL FEATURES Our products are in conformity with BS EN 13240/2001 (solid‐fuel household equipment) and subsequent amendments, and already in line with the draft of European standard BS EN 14785 (pellet‐heating household equipment). They are also in accordance with legal provisions, that incorporate the following directives: ‐ 89/336 EEC (EMC directive) and subsequent amendments; ‐ 73/23 EEC (low voltage directive) and subsequent amendments; ‐ 89/106 EEC (fitness for use) and subsequent amendments. Below is a short and simple note on the main performances and fittings of our product: PERFORMANCE Rated heat input [kW] Min 4.7 Max 14.5 Overall heat output [kW] Min 3.5 Max 11.9 ...
Weekly programmer Serial Two‐way radio control Optional GSM module Optional * values calculated on the basis of act 10/91 for rooms with thermal requirement of 30 kcal/hm and height of 3 m. The data given above are approximate; the producer company reserves the right to make any change in order to improve the product’s performance. The results in the table were obtained using certified pellet based on Austrian and German standards DIN 51731, DIN PLUS and ÖNORM M 7135. ...
Page 7
Binding agents % of pressed mass <2 2 <2 Not more than 20% of the pellet may have a length greater than 7.5 times its diameter D. The DIN prohibits the use of any added substance. However, this prohibition is not valid for small heating systems. DIN plus proposes the combination of the qualitative parameters proposed by standard DIN 51731 and by Austrian standard Önorm M 7135. The pellet, as also stipulated by current Italian legislation governing the commercial technology characteristics of fuels (DPCM 2.10.1995) must be produced exclusively with untreated wood chippings, with no other added materials. It is strictly prohibited to use any solid or liquid fuel other than the pellet to feed the stove. In order to optimise the use of the product we recommend using pellets which have been given a quality certificate by an authorised body. The use of pellets other than those directed by the installer may lead to heater malfunction and to the guarantee becoming invalid. ...
Page 8
A high moisture content in the pellet may cause it to crumble into dust, that creates a greater accumulation of residue in the brazier area and blockage of the fuel feed system (auger). ...
2 INSTALLATION INS . For a correct installation of the heater and to prevent the uprising of possible problems during running the heater, we are supplying some simple recommendations for the installation – according to regulations UNI 10683, UNI 9615 , UNI 9731 , UNI‐CIG 7129 and following updating referred to domestic gas use units. 2.1 Indoor positioning Our product is a heater that draws air that is necessary for its combustion process directly from the environment to be heated. For this reason and for the even more important reason of safety for the people using it, the heater ...
Page 10
In compliance with the indications reported under regulation UNI 10683 , the air inlets must have the following features : 1.They must have a clear space of not less than 80 cm ; 2.They must be made at a height close to the floor; 3.They must be suitably protected by a wire mesh or grille in such a way that the minimum passage space is not and may not be reduced; 4.They must be placed in such a way that they are not obstructed in anyway. The correct inflow of fresh air may be guaranteed by using apertures ...
Page 11
Having placed the outermost overall part of the heater at a distance of 80 cm from combustible and/or flammable material, if this distance cannot be maintained it is useful to arrange for heat protection to be provided ( regulations UNI 7129 , UNI 10683) Do not get close to, and above all do not touch with flammable material the outer surfaces of the combustion chamber that, after continuous product use, may reach high temperatures . ...
2.2 Fume extraction flue features The main features characterising the fume extraction flue are given. They are based on what is set out in standards UNI 7129 and UNI 10683/98: ‐ Inspection valves (I); ‐ Minimum height of the pipe directly connected to the heater fume extraction outlet must be between 2 ‐ 3 m; ‐ If it is necessary to have a horizontal section, it is advisable to make it with a maximum length of 1.5 m and with an incline of 3 ‐ 5% in order to help the fumes to escape; ‐ Use of a cowl that is wind‐resistant and rain‐resistant in order to avoid a change in the slight condition of overpressure the flue is in, (it is strongly recommended not to use a horizontal section at the end of the flue). The reduction in pressure in the flue is necessary so as to help the normal flow of fumes ...
Page 13
Figure 2.3: Fume extraction flue In the room where the heat generator must be installed, there must be no fume‐ extraction hoods already in existence or installed, in order to avoid depressing the atmosphere. The air vents must not be closed. Keep the flue clean, performing a cleaning operation at least once a year; it is also advisable to clean both the flue cowl and the fume pipe connection. ...
2.2.1 Outside wall extraction One of the installation solutions that may be adopted is that of placing the pellet heater close to an outside wall of the room so that the fumes are extracted directly to the outside (figure 2.4). Hereafter please find some recommendations reported under regulation UNI 7129 referred to this particular plant: ‐ Always guarantee that there is an inspection valve (I) that will allow effective and periodic cleaning to be carried out, and any condensation formed to be eliminated; ‐ The cowl (T) must be strictly windproof and rainproof; ‐ Insulate the fume extraction flue appropriately in the section where it goes through the wall. The fume extraction flue that is completely outside must be made of double‐wall stainless steel in order to guarantee that there is both greater resistance to atmospheric agents and correct fume extraction temperature. ...
2.2.2 Roof extraction by means of a traditional flue Pellet combustion fumes may be extracted also using a pre‐existing traditional flue (figure 2.5), provided that it is made to standard (refer to standard UNI 10683). Below is a short list of some of the main features given in the standard that characterise a good chimney (C): ‐ Suitable insulation and proofing particularly in its outer section that is exposed to the weather; ‐ Uniform internal section (there must be no section restrictions); ‐ Made of material that is resistant to high temperatures, the action of combustion products and the corrosive action of any condensation formed; ...
Page 16
We recommend to follow indications reported under regulations UNI 9615 and 9731 referred to dimensions of the chimney ( C ) and however to avoid using sections smaller than 100 mm . In the case where there are larger sections, it is necessary to insert a steel pipe (A) inside the masonry one (C), as shown in figure 2.6. The steel flue pipe must be suitable insulated with a high temperature‐resistant rock wool or vermiculite material (B). Figure 2.6: Example of extraction flue connection. In the case of fire in the extraction flue or duct, switch off the heater immediately and disconnect it from the house mains power supply. ...
Page 17
2.3 Connection to Central heating system In order to be able to operate, the heater must be suitably connected to a heating system. For this type of installation also, some simple suggestions are provided that will undoubtedly be helpful when installing the product (refer to regulation UNI 10412 and following up‐dating) The drainage cock is placed at the lowest point of the water circuit. We recommend to install the ball valve on the delivery water pipe and on the return water pipe ( please refer to the enclosed schematic drawing) . This will enable a quick and easy maintenance operation in case of need. All water heating installations should be designed, before product installation, and installed by a competent heating engineer in accordance with BS 5449: 1990; Code of Practice for Central Heating Systems for Domestic Premises. Further guidance is available from the following sources: BS EN 14336: 2004 Heating Systems in Buildings. Installation and commissioning of water based heating systems. BS EN 12828: 2003; Heating Systems in Buildings. Design of water based heating systems. BS EN 12831: 2003; Heating Systems in Buildings. Method for calculation of the design heat load. ...
The ball valve mounted on the inlet pipe must be open in normal system operating conditions in order to allow water to be added to the boiler. It may be closed when it is necessary to drain the system. The delivery and return pipes have a diameter of ¾". The correct functioning of the “ expansion box open ” requires that the expansion box is placed at a height not less than 7 meters in respect to the stove. The expansion vessel must be made of a covered vessel located above the highest point reached by the water in the system. The safety, inlet and outlet pipes must be protected from ice where this may occur. The safety pipe must allow the highest part of the generator to be in contact with the atmosphere ...
Page 19
For mounting our product parallel to a traditional gas boiler, according to the diagram shown it is necessary to connect a three‐way valve on the same pins (15 and 16) used for the recirculation pump. Figure 2.9: Control board wiring diagram 2.5 Instructions for mounting product covering For mounting the outer covering, simple instructions are provided: 1. Use a crosshead screwdriver. Lift the top (1) , remove the two screws holding the display . Take care when moving the top in order to avoid damaging or disconnecting the flat connecting cable between the board and the display ...
Page 20
3. Lift the side panel on the right hand side ( 2) . 4. Repeat the same process on the left hand side . 5. Dismount the lower panel ( 3) remove the screw placed on the base of the front door , remove the carter . Figure 2.10 : Pellet heater – instructions for mounting product For some models it might be necessary to lift and move the sheet‐metal top of the heater sideways in order to insert the side majolica tiles. 3.0 MAINTENANCE 3.1 SCHEDULED MAINTENANCE It is necessary to perform periodic maintenance of the heater in order to ensure constantly correct and effective operation. ...
Page 21
The cleaning operations described below must be carried out only when the heater is totally cold and disconnected from the household mains power supply. Disconnection from the household mains power supply is obtained by means of two simple operations: the first consists of turning off the switch placed at the back of the heater and the second of removing the product power cable (from the socket on the wall or from the rear of the apparatus). Figure 3.1: Pan grille The grille at the base of the pan (figure 3.1) is cleaned automatically during the heater extinguishing stage in order to ensure at all times the correct inflow of burning air in the combustion chamber. Should residue pellet accidentally remain, remove it by hand or with the ...
Page 22
By cleaning the surfaces of the exchanger pipes, the best possible heat exchange is always guaranteed. Figure 3.2. : Pellet loading When loading the pellet , the pellet must not fall into other areas than those designated for this purpose. ...
Page 23
Figure 3.3.: Fire door gaskets It might be necessary , at regular intervals , to clean the glass because it inevitably becomes dirty . Although this is a natural phenomenon , the frequency with which it occurs depends on the size and quality of the fuel used. Clean the glass when completely cold and using normal , non- abrasive detergents. Figure 3.4. : Ash trays ...
Page 24
panel itself is dismounted by loosening the screw positioned right in front of the burning pot ; the opening of the tray system is reached by removing the wing screws . Once the cleaning process has been completed and all the ashes have been removed by vacuum or by using the specific brush delivered together with the stove, all trays must be replaced and well tightened . The above cleaning process should be achieved using the specific cleaning brush supplied with the stove or a vacuum cleaner. At the end of the winter, we recommend emptying the fuel tank of residue pellet and storing it according to the methods suggested in chapter one. We recommend a thorough cleaning of both the flue and the fume junction (at least once during the whole operating season) in order to prevent fire risks. 3.2 Yearly maintenance This paragraph, intended expressly for engineers and all specialised personnel required to work on our product, is aimed at providing useful instructions in order to perform the necessary work for keeping the apparatus operating at a high level of efficiency. Unscheduled maintenance of the system must be carried out by qualified personnel when the heater is cold and disconnected from the household mains power supply. ...
Page 25
Figure 3.5. : Slide slits The slit will only be visible after its cover has been removed. Now it is possible to perform the cleaning, using the brush. Every 2 years it is necessary to clean the steel fan of the fume extractor and its housing. This part can be reached after having removed the side ceramic panels and after removing the four screws that hold the fan. The cleaning can be performed more easily with a vacuum cleaner. In this model the heat exchangers can be reached by means of the openings positioned at the rear of the stove. When replacing the covers of the side slits it will be necessary to remove the rear panel by loosening some screws. When replacing the parts and components , we would recommend the ...
Page 26
It is necessary to perform periodic maintenance of the ash box and the pan grille . The cleaning operations must be carried out only when the heater is totally cold . Should residue ashes accidentally remain , remove with a brush of a vacuum cleaner. With the aim to guarantee to the customer a perfect and long‐lasting running , we have limited the use of mobile components thus limiting the possibility of undersigned air infiltration within the combustion chamber which could cause irregularities in the combustion process. ...
‐ Door not tightly closed. The pan fills with fuel ‐ Primer resistance or the fume control thermal probe could be faulty. ‐ Electrical or electronic problem on the board. Stove in modulation status o with continuous ‐ Check the position of the two‐way remote control variations to water temperature in the boiler or unit and with special attention in the event that unexpected extinguishing of the flame the sensor of the remote control unit is positioned in a warm area ; ‐ Check the temperature fume temperature and check that the flues have been correctly installed; ‐ Check that the boiler temperature detecting probe is not faulty ; ‐ Check the functioning of the circulator Unexpected lowering of the flame ‐ Pellet hopper almost empty. ‐ The auger could be closed. ‐ The flue could be obstructed. ‐ Electrical or electronic problem on the board. ...
Although the surface temperatures reached by our product are not so high, we recommend you pay due care and attention when touching them. In particular, the outer surfaces of the combustion chamber may get red‐hot after intense use. Having placed the outermost overall part of the heater at a distance of 80 cm from combustible ...
Page 29
Allows access to the menu mode at any time. MENU Increases the operating power level . In menu mode its allows scrolling through menus and POWER MODIFICATION submenus. In menu mode it allows scrolling through SCROLLING THROUGH menus and submenus MENUS AND SUBMENUS Increase and decrease the thermostat setting MODIFICATION...
Page 30
1 SCREW Warning light ON : Screw is in operation 2 TIMER Warning light ON : Time schedule of extinguishing the PROGRAMMING heater by Timer FAN OR CIRCULATOR Warning light ON : Pump fan is active. AMBIENT THERMOSTAT Warning light ON : Room temperature higher than the temperature set in the ambient thermostat TIMER DAILY Warning light ON : The daily programming mode is set. TIMER WEEKLY Warning light ON : The weekly programming mode is set. TIMER WEEKEND Warning light ON : The weekend programming mode is set. 4.3. THE DISPLAY ...
Page 31
The condition of With the stove on, it displays the condition of operation and any operation error that has occurred. Error Menu mode In menu mode, it displays the name of the menus and the Submenus mode submenus, as well as the size values. Size values DISPLAY OF OPERATING CONDITIONS DISPLAY READOUT DISPLAY READOUT ...
This stage is entered if the temperature of the fumes exceeds a certain value. If within a preset SAFTEY time interval the temperature does not come under control again, the heater cuts out and them locks (appears on display as “SiC”). This condition is reached when not all the factors for passing on to the condition of normal LIGHTING RECOVERY operation occur (appears on display as “rec”). ...
Page 33
ERROR DISPLAYED Message on display MEANING Error : n. 1 with power supply The error can also occur when the heater is switched‐off Error : n. 2 with power supply The safety mode can be activated only with heater OFF Error for safety mode during fume high temperature caused by incorrect burning Encoder Error (only with heaters with embodied encoder) The error can be activated only when the encoder signal is not detected Encoder error (only with heaters with embodied encoder) The error can occur caused by the encoder not able to reach the set parameter) CLOCK error The error could occur due to problems with the clock Er01: . The pellet tank wall temperature has reached a temperature above 85°C. or if this temperature has been reached inside the boiler. In this case the heater can be lit only when the temperature has gone below 45°C . ...
Page 34
Er02: The error occurs when the pressure inside the flue is above 0.3 mbar in respect to the atmospheric pressure : The pressure inside the flue MUST ALWAYS BE LOWER than the atmospheric pressure . To this respect it is important to underline that the smoke extractor installed on the heater has the function to extract the fumes from the heater and does not push them through the flue. Er01/Er02: They occur when the detector probes , that should normally be closed , are now in an open modus caused by a safety device activated due to and event that has interrupted the circuit causing the malfunction of the probe. Er03: This occurs when the smoke temperature , due to malfunction , goes below the normal values. EnC0: This occurs when the smoke extractor , that is in operation and always under control , has a sudden stop during operation ...
Page 35
In order to optimise the product using different quality pellets and different installation methods , the heater allows an appropriate method of operation of combustion and heating to be chosen according to 4 methods . the methods run from 1 to 4 . Each number corresponds to a ventilation receipt . For example method n. 1 is suitable for operating a clearer pellet and with a flue installed according to regulations ( lower ventilation required)‐ method n. 4 is suitable for a darker pellet and with a non standard flue ( more ventilation required). At last whereas you are not able to locate an efficient combustion method , the manipulation of the parameters can be carried out by qualified engineers from Vokera Ltd . The engineers will analyze the situation and they will recommend a suitable solution for the situation . For a correct operation of the heater , we recommend to set power 4 or 5 during lighting sequence and for the following few minutes of functioning . As a further aid to the customer, the sequence of operations to perform in order to light the product for the first time is given: ...
Page 36
10 min.) until the NORMAL phase is reached. Error message could be displayed during lighting sequence Pellets must not be inserted into the pan by hand and hands should NEVER be introduced inside the pellet tank. The door should never be opened even during a power shortage or even if there has been a lock‐out event or even again during an auger block. The user must always activate the “switch‐off” procedure and solve the problem before a new lighting process. Extinguishing the product: Press the ON/OFF button for several seconds. The heater will initiate the extinguishing procedure according to the methods set during the design stage (the extinguishing time is variable and may go from a minimum of a few minutes up ...
Page 37
During use, do not obstruct the vent openings, that allow the combustion air to re‐circulate continuously, and the air intake located at the rear of the product. ...
4.5. SAFETY DEVICES The heater is fitted with some safety devices, such as: The fume temperature detector probe: This device allows the fume temperature to be read and the effective operation of the product to be monitored continuously; A water temperature detector probe . This allows the water temperature inside the boiler to be read and should the water temperature should reach 85°C then the user must operate the unlock safety switch positioned in the rear of the product. ...
Page 39
Message on Possible remedies Meaning Possible causes display Check that air intakes are not obstructed High temperature inside body of Ambient temperature too high ( heater ( T> 85°C) Pellet tank thermostat safety Er01 operation insufficient cooling inside the heater) Contact assistance centre Probe malfunction That that all parts of the flue are clean Obstruction in fume extraction flue Pressure switch safety operation , and free from obstruction Er02 pressure inside the flue (p> p +0.3mbar) Contact assistance centre Probe malfunction Accumulation of pellet during malfunctioning process Check the receipt and the variation Software error for low Heater installed and located in low range of the smoke temperature Er03 temperature of the smoke temperature ambient readout on the display Malfunctioning of the fume probes Fume extractor fan blocked or ...
Page 40
4.6. FUNCTIONS FROM THE KEYBOARD Changing the temperature value of the ambient thermostat : Hereafter please find the instructions to change the temperature value of the ambient thermostat in non‐menu mode. Note : The current temperature value is possible to display the thermostat temperature by pressing once only one of the buttons TEMPERATURE + or TEMPERATURE ‐. Press these buttons again to proceed to a variation of the value displayed. PROCESS INSTRUCTIONS BUTTON It is possible to display the current temperature value ...
The heater is equipped with a direct access menu ( through MENU button) to change the combustion power function . This will allow to change the power level This will allow to modify the temperature for the ambient thermostat Whereas you set the ambient thermostat at a low value , this could cause the continuous modulation status . 4.6.1. USER MENU MEN U Pressing button for three seconds you will have access the MENU. Press ing button ...
Page 42
WEEK END 2 Combustion menu 3 Clock menu 4 Manual pellet loading menu 4.7. Menu cron ( TIMER) This allows the heater automatic lighting/extinguishing intervals to be programmed. It is possible to programme the heater daily with 3 different time‐schedule programming bands . The programming mode requires that both the lighting and the extinguishing intervals are set . The extinguishing time band must be have a setting showing a switch-off time later than that of the lighting time-band.
Page 43
N.B.: When the time‐schedule ON has been set , the lower display will show: hen the time‐schedule OFF has been set , the lower display will show The lower display will show , from left time‐schedule programming bands available ( from 1 to 3 ); ON and OFF indicator Days of the week The minutes scroll from fifteen to fifteen ( i.e. : 20:00 , 20:15 , 20:30, 20:45). By just setting the hour at 23 it is possible to select for the minutes from the value 45 to the value 59 so as to be able to make a programming to straddle two days (over midnight). PROGRAMMING THE TIMER (CRON) INSTRUCTIONS BUTTON Press the button for 3 seconds and enter into Menu mode 1 2 Scroll through the menus and finally access to Cron (Timer) 3 Enter the Cron menu ( Timer) ...
Page 44
4 Scroll through undermenus and finally access to Giornaliero (Daily) 5 Enter the under menu Giornaliero ( DAILY ) Scroll through the Giornaliero (Daily) undermenu until reaching : Day of the week ( form Momday to Sunday) 6 Program band selected ( from 1 to 3) Time ON Enable the pre‐selected time‐schedule by pressing the ON/OFF button for 7 approx. 3 seconds Press button SET to access the modification mode. 8 The values selected ( hours and minuets )will start flashing 9 Change the selected value ( hour , minutes ) 10 Change the selected value 11 Save the modified settings 12 Select OFF time 13 Ripetere le operazioni da 8 a 11 per l’orario di OFF ...
Page 45
14 Exit the Daily Timer menu To activate the Time change the manual mode into Daily Mode ( this is 15 done from the Menu Mode) IThe timer will be activated only when you exit the manual mode and enter one of the other options : Daily , Weekly or weekend from the Menu mode. NOTE : MAKING TIMER PROGRAMME STRADDLE DAYS OVER MIDNIGHT) The OFF mode of one of the time‐scheme band referred to the selected day must be set at 23:59. The ON mode of the following day of the week on 00:00. EXAMPLE : In the under reported example , the programming band runs without interruption from 21:30 on a Tuesday over to 8:30 on Wednesday morning: SETTING THE TIME FOR TUESDAY ON OFF SETTING THE TIMER FOR WEDNESDAY ON ...
Page 46
This allows the heater lighting/extinguishing intervals to be programmed from Monday to Sunday . There are 3 different time‐schedule programming bands available ( each having an ON and OFF interval) The top display will show : Broken lines if the program has not been enabled Time of ON and time OFF if the programme has been set. N.B.: When the time‐schedule ON has been set , the lower display will show: hen the time‐schedule OFF has been set , the lower display will show The lower display will show , from left time‐schedule programming bands available ( from 1 to 3 ); ON and OFF indicator Days of the week The minutes scroll from fifteen to fifteen ( i.e. : 20:00 , 20:15 , 20:30, 20:45). By just setting the hour at 23 it is possible to select for the minutes from 45 to the value 59 so as to be able to make a programming to straddle two days ( midnight). ...
Page 47
3 Enter the Cron menu ( Timer) 4 Scroll through undermenus and finally access to Settimanale (Weekly) 5 Enter the under menu Settimanale Scroll through the Settimanale undermenu until reaching : 6 Program band selected ( from 1 to 3) Time ON Enable the pre‐selected time‐schedule by pressing the ON/OFF button for approx. 7 3 seconds Press button SET to access the modification mode. 8 The values selected ( hours and minuets )will start flashing 9 Change the selected value ( hour , minutes ) 10 Change the selected value 11 Save the modified settings 12 Select OFF time 13 Ripetere le operazioni da 9 a 11 per l’orario di OFF ...
Page 48
14 Exit the Weekly Timer menu To activate the Time change the manual mode into Weekly Mode ( this is done 15 from the Menu Mode) In order to complete the programming it is necessary for at least one programming band the have its ON and its OFF time set that will indicate the moment for the product to be turned ON and OFF. The timer will be activated only when you exit the manual mode and enter one of the other options : Daily , Weekly or weekend from the Menu mode. NOTE : making a TIMER programme to straddle two days ( over midnight) The OFF mode of one of the time‐scheme band referred to the selected day must be set at 23:59. The ON mode of the following day of the week on 00:00. EXAMPLE : In the under reported example , the programming band runs without interruption from 21:00 over to 8:30 on the next morning: SETTING TIME BAND N. 1 OFF SETTING TIME BAND N. 2 OFF ...
Page 49
4.7.3. PROGRAMMING THE WEEKEND TIMER It is possible to set the time‐schedule programming bands for the days from Monday to Friday and the same number of bands from Saturday and Sunday . Three time‐schedule programming bands are available ( each containing an On and OFF time‐ schedule) for the days from Monday to Friday and three time‐schedule programming bands available for Saturday and Sunday. The top display will show : Broken lines if the program has not been enabled Time of ON and time OFF if the programme has been set. N.B.: The display will show the ON time ‐ The display will show the OFF time The lower display will show , from left time‐schedule programming bands available ( from 1 to 3 ); ON and OFF indicator Day of the week PROGRAMMING THE TIMER (CRON) INSTRUCTIONS BUTTON Press the button for 3 seconds and enter into Menu mode 1 ...
Page 50
2 Scroll through the menus and finally access to Cron (Timer) 3 Enter the Cron menu ( Timer) 4 Scroll through undermenus and finally access to Weekend 5 Enter the undermenu Weekend Scroll through the weekend menu until reaching : ‐ Days to be included in the time‐schedule band ( Monday‐Friday or Saturday‐Sunday) 6 - Program band selected ( from 1 to 3) ‐ Time ON Enable the pre‐selected time‐schedule by pressing the ON/OFF button for 7 approx. 3 seconds Access the modification mode. 8 The values selected ( hours or minutes) will start flashing 9 Select the values to be changed 10 Change the selected value ...
Page 51
11 Save the selected values 12 Select the OFF time 13 Ripetere le operazioni da 9 a 11 per l’orario di OFF 14 Exit the Weekend Timer menu To activate the Time change the manual mode into Weekend Mode ( this is 15 done from the Menu Mode) In order to complete the programming it is necessary for at least one programming band the have its ON and its OFF time set that will indicate the moment for the product to be turned ON and OFF. The timer will be activated only when you exit the manual mode and enter one of the other options : Daily , Weekly or weekend from the Menu mode. NOTE MAKING TIMER PROGRAMME STRADDLE DAYS OVER MIDNIGHT) ...
Page 52
TIME‐SCHEME PROGRAMMED BAND 1 ON OFF TIME‐SCHEME PROGRAMMED BAND 2 ON OFF “RICE”( METHODS) ALLOWING APPROPRIATED OPERATION OF COMBUSTION. 4.8. Menu for selecting the combustion method. The top display will show the combustion method selected PROCEDURE INSTRUCTIONS BUTTONS Access the under menu by pressing the button for approx. 1 3 seconds Scroll through the menus and finally access COMBUSTION 2 menu Access the Combustion menu 3 Enter the modification mode. The selected values will start flashing 4 ...
Page 53
Change the parameter value 5 6 Save the settings 7 Exit the menu NOTE : The programme offers a selection of 4 rice , please select the most suitable according to the working conditions . Rice n. 4 will allow the max. air inlet to the combustion chamber. PROGRAMMING THE CLOCK MENU 4.9. Allows the time‐scheme value and that of the current date The top display shows the hour and the minutes The bottom display the days of the week PROCEDURE FOR PROGRAMMING THE CLOCK INSTRUZIONI BUTTONS Access the Menu mode and press the button for 3 1 seconds Scroll through the menus and finally access CLOCK 2 menu 3 Access the CLOCK menu ...
Page 54
6 Change the parameter value 8 Save all modified values 9 Exit the clock menu NOTE : It is important that this setting is achieved in a correct and appropriate manner. The automatic lighting / extinguishing of the heater will depend from this setting. 4.10 SCREW LOADING This allows to manually fill the screw during fuel loading Manual screw loading Instructions buttons Make sure that the heater is OFF 1 ...
Page 55
NOTE : When the screw is manually activated , the fume fan is also activated and the pressure switch is closed ( safety AT1 with contact normally open) this in order to feed the screw. NOTE : The heater MUST be switched –off. 4.11. MENU DISPLAYED The menus display allow you to check the status of the main values shown on the display SY215Evo in order to check the operations .The top display shows the sizes of the values selected. ...
Page 56
4.12 TIMER MODE Use button SET from the main board and scroll through the options until reaching one of the different MODES. Procedure for changing a MODE Instructions button 1 press for 3 seconds the ESC button 2 Menu DAILY ( Giornaliero) will be activated 3 Repeat process 1 to reach Weekly (settimanale) 4 Repeat process 1 to reach weekend (fine settimana) Repeat process 1 to return to manual process ( no warning ...
One‐way radio control Figure 5.1. : One-way Radio Control Through this radio control , that has a range of action of 10 meters , it is possible to regulate some heater operating parameters . Hereafter some functions performed by the SYTX control : − ON / OFF − Operating power increase/decrease Instructions on the interferences: The capacity of action of the device can meaningfully be reduced in case of noisy environment: other apparatuses such as wireless earphones or other electronic devices which could influence the performances of the system. After having checked that the apparatuses are within the limits of the heater, extinguish them or use them only if required avoiding useless pollution of the electromagnetic effects. ...
Page 58
5.1 ABOUT THE RADIO‐CONTROL CODES The radio‐control signal is detected by a code on the control board, and it is possible to change the code following, hereafter we are supplying the procedure. The correct transmission between radio‐control and control board, the transmission code must be the same on both the devices. The default code is planned on 0, and if the user needs to change the code, below is a description of the methods of changing the code: On the radio control: − Open the battery holding unit ‐ moving the cover toward right ; − Change the configuration of the dip‐switches; − Close the radio‐control again. On the board: − Cut‐off the power feed to the board; − Activate power feed to the board , pressing the radio‐control at the same time; − Wait (for about 5 second) for the audible signal sound coming from the board, this will ...
Page 59
Registered address: Vokèra Ltd Borderlake House Unit 7 Riverside Industrial Estate London Colney Herts AL2 1HG enquiries@vokera.co.uk www.vokera.co.uk www.vokera.ie Sales, General Enquires T 0844 391 099 F 0844 391 0998 Vokèra Ireland West Court, Callan Co Kilkenny T 056 7755057 F 056 7755060 Vokèra Limited reserve the right to change...