Summary of Contents for VOKERA Linea HE

  • Page 1 Linea HE High efficiency combi boiler Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.
  • Page 2: Table Of Contents

    INTRODUCTION Dear Customer Your Linea HE boiler has been designed to meet and exceed the very latest standards in gas central heating technol- ogy, and if cared for, will give years of reliable use and efficiency. Please therefore take some time to read these instructions carefully.
  • Page 3 Symbols description Summer current water pressure Spring outside sensor Autumn current appliance temperature Winter error code central heating temperature bar current mode of operation burner on frost protection on hot water temperature bar insufficient water pressure service request reset Linea HE...
  • Page 4: Things You Should Know

    Please take the time to fill out your guarantee FROST PROTECTION SYSTEM registration card. The completed warranty card The Linea HE is equipped with a built-in frost should be posted within 30 days of installation. protection system, this enables the boiler to over- BENCHMARK LOG BOOK ride the time controls –...
  • Page 5: Getting Started

    When the programmer/time clock or external ther- Water (DHW). In the summer mode the TSC mostats heating request has been satisfied, the (Temperature Stability Control) function is active. appliance will switch off automatically. All heating requests will be ignored. Linea HE...
  • Page 6: Adjusting The Operating Temperatures

    Call engineer 70/72/74 Temperature anomaly Call engineer 71/73 Temperature anomaly Wait 75/76 Wiring fault Call engineer Temperature anomaly Call engineer 80/90/91 Internal fault Call engineer Condense pipe blocked Call engineer 93/95 Condense pipe blocked Wait Wiring fault Call engineer Linea HE...
  • Page 7: Information Mode

    Info 1 outside temperature (only if outside sensor connected) (fig. 3) Fig.4 Info 2 water pressure (fig. 4) Info 3 CH temperature set (fig. 5) Info 4 DHW temperature set (fig. 4.6) Fig. 5 Fig. 2 Fig. 6 Fig. 3 Linea HE...
  • Page 8: How To

    If the appliance requires to be reset frequently, it Safety valve valve outlet may be indicative of a fault, please contact your installer or Vokera Customer Services for further advice. Fig. 4 HOW TO SHUT DOWN THE SYSTEM FOR SHORT PERIODS...
  • Page 9: What If

    Advice for homeowners Please contact Vokera Customer Service (0870 333 0220 (UK) or 05655057 (ROI) if you would prefer a Vokera service engineer or agent to service your appliance. Alternatively your local CORGI registered engineer may be able to serv- ice the appliance for you.
  • Page 10 NOTE Linea HE...
  • Page 11 Linea HE...
  • Page 12 Registered address: Vokèra Ltd Borderlake House Unit 7 Riverside Industrial Estate London Colney Herts AL2 1HG enquiries@vokera.co.uk www.vokera.co.uk www.vokera.ie Sales, General Enquires T 0844 391 099 F 0844 391 0998 Vokèra Ireland West Court, Callan Co Kilkenny T 056 7755057 F 056 7755060 Vokèra Limited reserve the right to change...