Trouble Shooting; Repairs; Environmetal Protection; Technical Specifications - Elektra Beckum Mega 600 D Operating Instructions Manual

Hide thumbs Also See for Mega 600 D:
Table of Contents

Advertisement

coil air hose.
Stock-no. 090 101 3845
Accessory Kit LPZ 2 (not illustrated)
contains change handle with blow
gun, tyre inflator gauge, paint spray
gun, self-storing coil air hose.
Stock-no. 090 105 5971

7. Trouble Shooting

A
Danger!
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the compressor has
come to a complete stop.
− Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts
remain
on
machine.
Compressor does not run:
No mains voltage.
− Check cables, plug, outlet and
mains fuse.

10. Technical Specifications

Suction capacity
Free air delivery (volume flow rate)
Filling rate
Working pressure (compression end pressure)
Pressure vessel volume
No. of air outlets
Compressor pump model
No. of cylinders
Speed (compressor pump)
Motor capacity
Supply voltage (50 Hz)
Rated current
Fuse protection min.
Degree of protection
Max. overall cable length when using extension cables:
2
– at 3 x 1.0 mm
lead cross section
2
– at 3 x 1.5 mm
lead cross section
2
– at 3 x 2.5 mm
lead cross section
Oil grade (compressor pump)
Required oil quantity (compressor pump)
Dimensions length x width x height
Weight
Sound pressure level L
PA
Sound power level L
WA
Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
Compressor
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
Drain cock on cup of filter/regulator
unit open.
− Close drain cock.
Check valve leaky.
− Have check valve serviced by
or
in
the
qualified service centre.
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
at 4 m max.
was
stopped
by
l/min
l/min
l/min
bar
l
-1
min
kW
V
A
A
m
m
m
l
cm
kg
dB (A)
dB (A)
ENGLISH
− Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.

8. Repairs

A
Danger!
Repairs to electric tools must
be carried out by qualified electrici-
ans only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the electric tool.

9. Environmetal protection

The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
480
330
370
10
90
2
B 4900 B
2
1275
3.0
400
6.2
10 (time-lag)
IP 54
15
25
40
SAE 40
1.1
123 x 56 x 91
98
73 ± 3
93
15

Hide quick links: