2. Use lubricants sparingly during assembly; a light film is all
that is required.
3. Use a small brush or cotton swab to apply grease directly to
o-rings where they are not accessible (QC fitting, M22 fitting).

Connect Hoses and Water Supply

NOTICE Use ONLY cold water (less than 100°F).
1. Attach garden hose (50 ft. / 15.24 m maximum) to water
supply.
2. Run water through garden hose for 30 seconds to flush the
hose of debris. Turn off water.
3. Confirm that water inlet screen (A) is installed in water inlet
coupling (B).
B
NOTICE DO NOT run the pump without the water supply
connected and turned on.
• Damage to equipment resulting from failure to follow this
instruction will void warranty.
4. Attach garden hose (C) to the water inlet coupling (B). Tighten
by hand.
5. Uncoil high pressure hose completely from hose reel.
6. Attach end of high pressure hose to the spray gun. Press red
button (D) on spray gun, then insert end of high pressure
hose (E) into gun until it SNAPS into place. Release the red
button and make sure connection is secure.
D
E

Connect Nozzle Extension and 7-in-1 Nozzle

1. Turn ON water, point gun in a safe direction, press trigger
lock button (F), then squeeze trigger to purge pump system
and spray gun of air and impurities.
8
2. Attach nozzle extension to spray gun. Tighten by hand.
3. Pull back on collar of nozzle extension, insert 7-in-1 nozzle
and release collar. Tug on 7-in-1 nozzle to make sure it is
securely in place. See How to Use 7-in-1 Nozzle.
A
4. Turn OFF water and release trigger. Point gun in a safe
C
direction and make sure trigger cannot be squeezed.

Checklist Before Starting Pump Motor

Review the unit's assembly to ensure you have performed all of
the following.
1. Be sure to read Operator Safety and Operation before using
the electric pressure washer.
2. Check for properly tightened hose connections.
3. Check to make sure there are no kinks, cuts, or damage to
hoses.
4. Provide a proper water supply at an adequate flow.
5. Plug electrical power cord into a dedicated electrical circuit
rated for 120 Volts AC at 15 Amps that is properly installed
in accordance with all local codes and ordinances. Check that
circuit is not used to supply any other electrical needs.

Servicing Of A Double-Insulated Appliance

In a double-insulated product, two systems of insulation are
provided instead of grounding. No grounding means is provided
on a double-insulated product, nor should a means for grounding
be added to the product. Servicing a double-insulated product
requires extreme care and knowledge of the system, and should
be done only by qualified service personnel. Replacement parts
for a double-insulated product must be identical to the parts they
replace. A double-insulated product is marked with the words
"DOUBLE INSULATION" or "DOUBLE INSULATED."
The symbol
F
means DOUBLE-INSULATED APPLIANCE.
BRIGGSandSTRATTON.COM