Furnace Specifications - Amana AMH950453BXA Series Technical Manu Technical Manualal

40" up to 96% gas furnace
Hide thumbs Also See for AMH950453BXA Series:
Table of Contents

Advertisement

FURNACE SPECIFICATIONS

MODEL
BTUH
*
Natural Gas Input
Natural Gas Output
LP Gas Input
LP Gas Output
A.F.U.E.
Rated External Static (" w.c.)
Temperature Rise (°F)
ID Blower Pressure Switch Trip Point (" w.c.)
Front Cover Pressure Switch Trip Point (" w.c.)
Blower Wheel (D" x W")
Blower Horsepower
Blower Speeds
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
Transformer (VA)
Primary Limit Setting (°F)
Auxiliary Limit Setting (°F)
Rollout Limit Setting (°F)
Fan Delay On Heating
(3)
Off Heating
Fan Delay On Cooling
Off Cooling
Gas Supply Pressure (Natural/Propane) ("w.c.)
Manifold Pressure (Natural/Propane) ("w.c.)
Orifice Size (Natural/Propane)
Number of Burners
Vent Connector Diameter (inches)
Combustion Air Connector Diameter (inches)
Shipping Weight (lbs.)
* Natural Gas BTU/h. For altitudes above 2,000', reduce input rating 4% for each 1,000' above sea level. Low-firerate is 75% of high-fire rate
(1)
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: May use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
(3)
Off Heating - this fan delay timing is adjustable (100 and 150 seconds). Furnaces are shipped with 150 second off delay.
(4)
See Installation Instructions for appropriate vent diameter, length and number of elbows.
(5)
See Installation Instructions for appropriate combustion air pipe diameter, length and number of elbows.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in
accordance with all national and/or local electrical codes. Use copper wire only.
1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation.
2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only
be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers method or in accordance with the "A.S.H.R.A.E.
GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal
to or less than the heating capacity. Output based on D.O.E. test procedures.
4. Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
*MH95
0453BXA*
46,000
44,200
41,400
39,800
96.1%
.20 - .50
35 - 65
-1.10
-0.37
10 x 8
1/3
4
1200
115-60-1
( 1)
9.4
(2)
15.0
40
150
150
200
30 secs.
150 secs.
6 sec.
45 secs.
7 / 11
3.5 / 10
43 / 55
2
(4)
2
(5)
2
120
*MH95
*MH95
*MH95
0703BXA*
0704CXA*
0904CXA*
69,000
69,000
92,000
66,300
66,300
88,400
62,100
62,100
82,800
59,700
59,700
79,600
96.1%
96.1%
96.1%
.20 - .50
.20 - .50
.20 - .50
30 - 60
35 - 65
30 - 60
-0.95
-1.10
-1.20
-0.37
-0.37
-0.60
10 x 8
10 x 10
10 x 10
1/3
1/2
4
4
1200
1600
1600
115-60-1
115-60-1
115-60-1
9.4
13.8
13.8
15.0
15.0
15.0
40
40
160
160
150
150
200
200
30 secs.
30 secs.
30 secs.
150 secs.
150 secs.
150 secs.
6 sec.
6 sec.
6 sec.
45 secs.
45 secs.
45 secs.
7 / 11
7 / 11
7 / 11
3.5 / 10
3.5 / 10
3.5 / 10
43 / 55
43 / 55
43 / 55
3
3
2
2
2
2
123
125
*MH95*****XA*
*MH95
*MH95
0905CXA*
0905DXA*
92,000
92,000
88,400
88,400
82,800
82,800
79,600
79,600
96.1%
96.1%
.20 - .50
.20 - .50
30 - 60
35 - 65
-1.35
-1.10
-0.10
-0.37
11 x 10
11 x 10
1/2
3/4
3/4
4
4
4
1800
2000
115-60-1
115-60-1
13.2
13.2
15.0
15.0
40
40
40
150
130
160
150
120
150
200
210
200
30 secs.
30 secs.
150 secs.
150 secs.
6 sec.
6 sec.
45 secs.
45 secs.
7 / 11
7 / 11
3.5 / 10
3.5 / 10
43 / 55
43 / 55
4
4
4
2
2
2
2
2
2
144
146
151
*MH95
1155DXA*
115,000
110,500
103,500
99,500
96.1%
.20 - .50
35 - 65
-1.10
-0.60
11 x 10
3/4
4
2000
115-60-1
13.2
15.0
40
160
160
200
30 secs.
150 secs.
6 sec.
45 secs.
7 / 11
3.5 / 10
43 / 55
5
2
2
163
11