12.1.8. Setting Water Outlet Temperature For Heat Mode
• The set temperature define the parameters for the outdoor ambient temperature dependent operation of the unit. Where by the
internal water setting temperature is determined automatically depending on the outdoor temperature. The colder outdoor
temperatures will result in warmer water and vice versa. The user has the possibility to shift up or down the target water
temperature by control panel setting.
• Change in setting water outlet temperature is updated every 30 minutes.
12.1.8.1. Heating Mode Operation Time Chart
Exp:
1. 3 ways valve control:
• 3 ways valve switch and fix to room side.
2. Heat pump operate follow normal heating operation.
3. Backup heater operate follow normal operation.
4. Solar 3 way valve operates follow solar operation specification
5. 2 ways valve control:
• 2 ways valve opens.
52