4 Applications

10
4 Applications
The Vaillant VANTAGE may only be connected to a
Vaillant boiler.
No other indirect heat source may be used.
The following Vaillant boilers are available for use with
the VANTAGE cylinders:
THERMOcompact system boilers
615 E (VU 152-5)
620 E (VU 202-5)
624 E (VU 242-5)
628 E (VU 282-5)
ecoMAX - Condensing system boilers
613/2 E (VU 126)
618/2 E (VU 196)
622/2 E (VU 246)
4.1 Typical applications
– Single bathroom property:
VANTAGE 120
– Single bathroom property with an en-suite shower
room:
VANTAGE 120 / 150
– Two bathroom property:
VANTAGE 150
– Two bathroom property with an en-suite shower room:
VANTAGE 150 / 200
– Larger properties:
VANTAGE 200
Commercial use: size depending upon hot water
requirements
Note:
1 Select the appropriate Vaillant boiler to match
the heating load (with the normal allowance for
heating up from cold) plus an allowance for
heating the hot water cylinder. Typically it is
practice to allow an additional 2-3 kW for the
hot water production.
2 Consideration should be given to the use of a
larger size of cylinder than shown above
where high water demands are likely.