5.0 p e r fo r m a n c e t e s t s
5.2
Performance test procedure
For test point
(TP)
references, see section 6.0 Test Points.
No
Action
5.2.19.
Right channel
check mute
operation
reverse polarity
5.2.20.
Reassemble unit
5.2.21.
Noise check
5.2.22.
Check
operation of
remote
controller
5.2.23.
Clean with
damp cloth
1
.2 ms/div
400 mV/div
2
.2 ms/div
2.00 V/div
Test Equipment
Multimeter set to
diode test
Connect to CD
player and
preamplifier and
play a TAG
McLaren Audio Test
Tracks CD
Details
Connect positive probe to 0 V
Connect negative probe to input socket
signal pin
(TP
22).
Make sure amplifier mutes.
Disconnect positive probe.
Make sure mute relay resets (not muted).
Relay will click.
Remove all leads
Reconnect loudspeaker connections and
listen to audio output for good audio
performance.
Check remote funtions:
volume
input selection
muting
Figure 5.2 Protection circuit waveforms
(TP
0).
1
2