Performance Test Procedure - Audiolab 8000S Service Manual

Integrated amplifier
Hide thumbs Also See for 8000S:
Table of Contents

Advertisement

5.0 p e r fo r m a n c e t e s t s
5.2

Performance test procedure

For test point
(TP)
references, see section 6.0 Test Points.
No
Action
5.2.1.
Switch off AC
power button
5.2.2.
Connect
amplifier as
shown in
Figure 5.1
5.2.3.
Switch on AC
power button
5.2.4.
Adjust volume
knob to
maximum
5.2.5.
Measure output
of preamplifier
5.2.6.
Measure output
of power
amplifier
5.2.7.
Reduce
VOLUME
knob to
minimum
5.2.8.
Set OUTPUT
to 20 V rms
5.2.9.
Measure
distortion at
1 kHz
Test Equipment
Audio Analyser
output connected to
both left and right
CD inputs
8 Ω load
Audio Analyser
output: 1kHz,
100 mV rms
Multimeter set to
mV AC
Audio Analyser
output: 1kHz,
100 mV rms
200Hz HP filter on
A-weighted filter off
Audio Analyser
output: 1kHz,
1 V rms
200Hz HP filter on
A-weighted filter off
Audio Analyser
output 1kHz,
1 V rms
200Hz HP filter on
A-weighted filter off
Details
Output frequency:
1 kHz sine wave
Output voltage:
100 mV rms
Reading settings:
AC level, Auto,
200 Hz HP filter on
A-weighted filter off
Select cd using INPUT selector knob.
Select pre using MODE selector knob.
Measure output of left and right PRE
AMP sockets.
Voltage should be 286 mV rms
±10 mV rms.
Select integrated using MODE selector
knob.
Measure output of left and right
loudspeaker terminals.
Voltage should be 8 V rms ±0.2 V rms.
Increase volume until amplifier OUTPUT
is 20 V rms. If signal is increased further,
amplifier will begin to clip.
Distortion of left and right channels should
be <0.006%
12