FITTED EQUIPMENT- The Alde Heating System
7. *Pump speed
The circulation pump's capacity can be remote
controlled from the panel. NOTE! A pump with
remote control must be installed in order that
this function can be used (see the manual for
the vehicle, boat or building).
8. *LPG bottle full/empty
This function is used in combination with
the cylinder changeover (DuoComfort or
DuoControl) and indicates if the LPG bottle is
full or empty. This function can also be used
to control defroster heating of the cylinder
changeover using an EisEx defroster. NOTE!
The cylinder changeover (DuoComfort or
DuoControl) must be installed in order for
this function to work (see the manual for the
vehicle, boat or building).
9. Automatic anti-bacterial mode (legionella)
At 02.00 at night (if the clock is set) the
boiler starts and works according to "Hot
water boost" (see section 5). This is in order
to reduce the risk of legionella. The function
is deactivated in the factory setting.
10. Offset (temperature adjustment)
Using this function, you can calibrate the
temperature on the panel if you notice
that
the
temperature
(the
room temperature) is not the same as the
temperature shown on the panel. This also
applies to outdoor temperature.
11. Button sound
With this function, you can activate or
deactivate the button sound.
The button sound is activated in the factory
setting.
12. Screen Brightness
Brightness: The brightness of the display
(working mode) can be adjusted from 1 to 10.
Factory setting is 5.
Standby brightness:
Off: Used to turn the display's backlighting
off so that the display is turned off (becomes
dark) in standby mode (the LED is still active).
On: Used to activate the backlighting in the
display (low lighting) in standby mode (the
LED is still active). Factory setting is On.
stabilised
13. Language
This function is used to reset the screen
between
different
languages are: English, French and German.
On the other hand, the service menu is only
in English (see section 10.1).
14. Tools / Key
Under Tools / Key you can lock or unlock
access to the tool menu.
15. *External start
This function is used when starting the boiler
from the outside, for example, with GSM. When
external start has been activated, the control
panel's On/Off button must be switched off
(see the assembly setting manual for external
start). NOTE! To use this function, an external
start installation is required (see the manual
for the vehicle, boat or building).
*230 V
This function is used in connection with
starting the boiler when connection of 230
V to vehicle takes place from outside. When
the 230 V function has been activated
the control panel's on/off button must be
turned off, but 12 V must be connected (the
vehicle's main switch is on). Before turning
off the control panel with the on-/off button
set the parameters/functions that you want
the boiler to have when it starts (230 V is
connected).
16. *Load monitor
This function is used to prevent the 230V
fuses being overloaded. If the total power
consumption of the vehicle, boat or building
exceeds the set value, the boiler's power
will be automatically reduced. On account of
voltage variations and tolerances, different
languages.
Available
setting levels can be selected (for example, for
6A fuse, one can choose 6 or 7 Amp setting).
If the fuse does not hold, choose a lower
set value. The function is deactivated in the
factory setting. NOTE! The load monitor has