Model
Minimum Gas Consumption Btu/h
Maximum Gas Consumption Btu/h
Hot water capacity, (50°F rise)
Hot water capacity, (35°F rise)
Factory TemperatureSetting
Maximum Temperature Setting
Minumum Temperature Setting
Weight
Efficiency Rating
Noise level
Normal
Electrical
Standby
Consumption
Anti-frost Protection
By-Pass Control
Minimum
Natural Gas
Gas Supply
Propane
Pressure
Maximum
Natural Gas
Gas Supply
Propane
Pressure
Type of Appliance
Operation
Exhaust System
Approved Gas Type
Connections
Ignition System
Electric Connections
Water Temperature Control
Water Supply Pressure
Maximum Water Supply Pressure
Remote Control Cable
Safety Devices
Rinnai is continually updating and improving products, therefore, specifications are
subject to change without prior notice. Local, state, provincial and federal codes must be
adhered to prior to installation.
Rinnai America
S P E C I F I C A T I O N S
V2532FFU
V2532FFUC
0.6 to 6.5 GPM
0.6 to 8.5 GPM
104°F
140°F
Electronic
Temperature controlled continuous flow gas hot water system.
With or without remote controls, mounted in kitchen, bathroom, ect.
Direct Vent - Forced Combustion
Natural Gas or Propane - Ensure unit matches gas type it's being installed on.
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Appliance: AC 120 Volts, 60Hz.
Simulation Feedforward and Feedback.
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Non-Polarized Two Core Cable
Remaining Flame (OHS) 207°F Bi-Metal Switch
Automatic Frost Protection - Bi-Metal Sensor & Anti-Frost Heaters
Combustion Fan RPM Check - Integrated Circuit
Over Current - Glass Fuse (3 amp)
If remote fails or becomes disconnected unit defaults to 100°F with water flowing, this is an anti-scald feature.
2
V2520FFU
15,000
180,000
0.6 to 5.3 GPM
0.6 to 5.3 GPM
140°F
104°F
185°F
140°F
98°F
49 Lbs.
87%
49 dB (A)
75 watts
5.5 watts
100 watts
Fixed
6" W.C.
10" W.C.
10.5" W.C.
13.5" W.C.
Direct Electronic Ignition
Remote Control: DC 12 Volts (Digital)
150 PSI
Flame Failure - Flame Rod
Boiling Protection - 210°F
Thermal Fuse 264°F
V2520FFUC
140°F
185°F
120°F
None
FF Models