Transceiver Calibration; Set-Up - Midland Syn-Tech 70-342XL Service Manual

Vhf (wide band)
Table of Contents

Advertisement

TRANSCEIVER CALIBRATION
7 0 - 3 4 2 ~ ~ / 4 4 2 ~ ~
SUGGESTED TEST EQUIPMENT FOR TRANSMITTER CALIBRATION
Test Instrument
Instrument Capabilities
Instrument Type
DC Power Supply
13.8 VDC,
1 0 amps
Power Mate BPA-20PF
Wattmeter
5 0 watts, 136-174 MHz
Bird model 4 3 with 50C
element and 5 0 ohm load
Deviation Meter
136-174 MHz.
+/-5KHz range
p/o Cushman CE-31A
Frequency Meter or
136-174 MHz
p/o Cushman CE-31A or.
Frequency Counter
2.0 ppm accuracy
Heath SM-4120
Audio Generator
0-10 KHz sine-wave,
Heath SG-5218
0-5 Vrms output
CALIBRATION SET-UP
POWER SUPPLY