■ Technical Data
Model
Phase
Voltage/Freq
V
Wattage
kW
Max. amp.load
A
Min. required circuit
breaker*
A
Min. wire size AWG cooper
Min. water flow to activate
GPM / L/min.
Working pressure PSI/bar
lb
Weight
kg
Product Dimensions
mm
in
Water connections
NPT
Note: *suitable recognized strain relief means shall be provided when the product installed.
11.02"
WIRE CONNECTIONS TO BREAKERS
L1
DOUBLE POLE BREAKER
40 Amp MS150
50 Amp MS180
60 Amp MS210
MS80C2P_U
MS100C2P_U
1
1
240 V/60Hz
240 V/60Hz
8kw
10kw
34
42
45
60
8
6
0.53 / 2
0.53 / 2
7.7
7.7
3.5
3.5
385x260x93
385x260x93
15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7" 15.2"x10.2"x3.7"
1/2"
1/2"
(MS150, MS180, MS210)
L2
MS120C2P_U
MS150C2P_U
1
240 V/60Hz
240 V/60Hz
12kw
50
60
6
0.53 / 2
0.85 / 3.2
Max.150/10
7.7
3.5
385x260x93
385x260x93
1/2"
(MS150, MS180, MS210)
L1
L2
DOUBLE POLE BREAKER
40 Amp MS150
50 Amp MS180
60 Amp MS210
4
MS180C2P_U
1
1
240 V/60Hz
15kw
18kw
63
75
2 X 40
2 X 50
2 X 8
2 X 8
0.85 / 3.2
12.1
12.1
5.5
5.5
385x260x93
3/4"
3/4"
E / G
EARTH/
GROUND
MS210C2P_U
1
240 V/60Hz
21kw
88
2 X 60
2 X 8
0.85 / 3.2
12.1
5.5
385x260x93
3/4"