Maintenance; Cleaning Your Garage Door; Painting Your Garage Door; Operation And Maintenance - Overhead door 301 Installation Instructions Manual

Carriage house collection
Table of Contents

Advertisement

Maintenance

Cleaning Your Garage Door

IMPORTANT: DO NOT USE A PRESSURE WASHER ON YOUR GARAGE DOOR!
While factory-applied finishes on garage doors are durable, it is desirable to clean them on
a routine basis. Some discoloration of the finish may occur when a door has been exposed
to dirt-laden atmosphere for a period of time. Slight chalking may also occur as a result of
direct exposure to sunlight.
Cleaning the door will generally restore the appearance of the finish. To maintain an aestheti-
cally pleasing finish of the garage door, a periodic washing of the garage door is recom-
mended.
THE FOLLOWINg CLEANINg SOLuTION IS RECOMMENDED:
A mild detergent solution consisting of one cup detergent (with less than 0.5% phosphate)
dissolved into five gallons of warm water will aid in the removal of most dirt.
NOTE: The use of detergents containing greater than 0.5% phosphate is not recommended
for use in general cleaning of garage doors.
NOTE: Be sure to clean behind weatherstrips on both sides and top of door.
CAuTION: NEVER MIx CLEANSERS OR DETERGENTS WITH BLEACH.
gLASS CLEANINg INSTRuCTIONS
Clean with a mild detergent solution (same as above) and a soft cloth. After cleaning, rinse
thoroughly.
ACRyLIC CLEANINg INSTRuCTIONS
Clean acrylic glazing with nonabrasive soap or detergent and plenty of water. Use your bare
hands to feel and dislodge any caked on particles. A soft, grit-free cloth, sponge or chamois
may be used to wipe the surface. Do not use hard or rough cloths that will scratch the acrylic
glazing. Dry glazing with a clean damp chamois.
NOTE: Do not use any window cleaning fluids, scouring compounds, gritty cloths or solvent-
based cleaners of any kind.

Painting Your Garage Door

SuRFACE PREPARATION FOR PAINTINg:
Wax on the surface must be removed or paint peeling/ flaking will result. To remove this
wax, it will be necessary to lightly scuff the surface with a fine steel wool pad saturated with
soapy water. A final wipe and rinse should be done with clean water only to remove any loose
particles and any soapy film residue.
Surface scratches, which have not exposed the metal substrate, can be lightly buffed or
sanded with 0000 steel wool or no. 400 sand paper to create a smoother surface. Care must
be taken to not expose the substrate under the paint. Once the substrate is exposed, the
likelihood for rusting is greatly increased.
If substrate is exposed, it must be treated to prevent rust from forming. Sand the exposed
area lightly and paint with a high quality metal primer specifically intended for galvanized
surfaces to protect the area from corrosion. Allow for drying time on primer can label before
applying topcoat.
The surface of the factory-applied finish, that is being painted, must not be too smooth, or
the paint will not adhere to it. It is advisable to test in an inconspicuous area, to evaluate
adhesion. If poor adhesion is observed, surface preparation for painting the factory-applied
finish must be repeated until desired results are achieved. Again, care must be taken to not
expose the substrate under the paint.
PAINTINg:
After surface has been properly prepared, it must be allowed to dry thoroughly, and then
coated immediately with premium quality latex house paint. Follow paint label directions
explicitly. Oil base or solvent base paints are not recommended. Please note that if substrate
is exposed and not properly primed, painting with latex paint may cause accelerated rusting
of the steel in the exposed area.
NOTES:
1. Re-painting of finish painted steel doors cannot be warranted, as this condition is totally
beyond the door manufacturer's control.
2. Consult a professional coatings contractor if in doubt about any of the above directions.
3. Follow directions explicitly on the paint container labels for proper application of coatings
and disposal of containers. Pay particular attention to acceptable weather and temperature
conditions in which to paint.

Operation and Maintenance

OPERATINg yOuR gARAgE DOOR:
Before you begin, read all warning labels affixed to the door and the installation instruc-
tions and owner's manual. When correctly installed, your Overhead garage door will operate
Please Do Not Return This Product To The Store. Contact your local Overhead Door Ribbon Distributor. To find your local Overhead Door Ribbon
Distributor, refer to your local yellow pages business listings or go to the Find a Ribbon Distributor section online at www.OverheadDoor.com.
smoothly. Always operate your door with controlled movements. Do not slam your door or
throw your door into the open position, this may cause damage to the door or its compo-
nents. If your door has an electric opener, refer to the owner's manual to disconnect the
opener before performing manual door operation below.
Manual door operation:
For additional information on manual garage door operations go to www.dasma.com and
reference TDS 165.
IMPORTANT: DO NOT PLACE FINGERS OR HANDS INTO SECTION JOINTS WHEN OPENING
AND/OR CLOSING A DOOR. ALWAYS USE LIFT HANDLES / SUITABLE GRIPPING POINTS
WHEN OPERATING THE DOOR MANUALLY.
Opening a Door: Make sure the lock(s) are in the unlocked position. Lift the door by using the
lift handles / suitable gripping points only. Door should open with little resistance.
Closing a Door: From inside the garage, pull door downward using lift handles / gripping point
only or a high friction area only. If you are unable to reach the lift handles/ suitable gripping
points only, use pull down rope affixed to the side of door. Door should close completely with
little resistance.
using an electric operator:
IMPORTANT: PULL DOWN ROPES MUST BE REMOVED AND LOCKS MUST BE REMOVED OR
MADE INOPERATIVE IN THE UNLOCKED POSITION.
When connecting a drawbar (trolley type) garage door operator to this door, an drawbar
operator and or drawbar operator bracket must be securely attached to the top section of
the door, along with any struts provided with the door. Always use the drawbar operator and
or drawbar operator bracket supplied with the door. To avoid possible damage to your door,
Overhead Door Corporation recommends reinforcing the top section with a strut (may or may
not be supplied). The installation of the drawbar operator must be according to manu-
facturer's instructions and force settings must be adjusted properly. Refer to the owner's
manual supplied with your drawbar operator for complete details on installation, operation,
maintenance and testing of the operator.
MAINTAININg yOuR gARAgE DOOR:
Before you begin, read all warning labels affixed to the door and the installation instruc-
tions and owner's manual. Perform routine maintenance steps once a month, and have the
door professionally inspected once a year. Review your Installation Instructions and Owner's
Manual for the garage door. These instructions are available at no charge from Overhead
Door Corporation, 2501 South State Highway 121, Suite 200, Lewisville, Tx., 75067, or at
www.odcexchange.com. For additional information on garage door/operator maintenance go
to www.dasma.com and reference TDS 151, 167 and 179.
Monthly Inspections:
1. Visual Inspection: Closely inspect jambs, header and mounting surface. Any wood found
not to be structurally sound must be replaced. Inspect the springs, counterbalance lift cables,
track rollers, pulleys, rear back hangs and other door hardware for signs of worn or broken
parts. Tighten any loose screws and/or bolts. Check exterior surface of the door sections
for any minor cracks. Verify door has not shifted right or left in the opening. If you suspect
problems, have a trained door system technician make the repairs.
WARNINg
WARNINg
gARAgE DOOR SPRINgS, COuNTERBALANCE LIFT CABLES, BRACk-
ETS, AND OTHER HARDWARE ATTACHED TO THE SPRINgS ARE uNDER
ExTREME TENSION, AND IF HANDLED IMPROPERLy, CAN CAuSE SEVERE
OR FATAL INJuRy. ONLy A TRAINED DOOR SySTEMS TECHNICIAN
SHOuLD ADJuST THEM, By CAREFuLLy FOLLOWINg THE MANuFAC-
TuRER'S INSTRuCTIONS.
WARNINg
WARNINg
NEVER REMOVE, ADJuST, OR LOOSEN THE BOLTS, SCREWS AND/OR
LAg SCREWS ON THE COuNTERBALANCE (END OR CENTER BEARINg
BRACkETS) SySTEM OR BOTTOM CORNER BRACkETS OF THE DOOR.
THESE BRACkETS ARE CONNECTED TO THE SPRINg(S) AND ARE uNDER
ExTREME TENSION. TO AVOID POSSIBLE SEVERE OR FATAL INJuRy,
HAVE ANy SuCH WORk PERFORMED By A TRAINED DOOR SySTEMS
TECHNICIAN uSINg PROPER TOOLS AND INSTRuCTIONS.
Torsion Springs: The torsion springs (located above the door) should only be adjusted by a
trained door systems technician. DO NOT attempt to repair or adjust torsion springs yourself.
Extension Springs: A restraining cable or other device should be installed on the extension
spring (located above the horizontal tracks) to help contain the spring if it breaks.
2. Door Balance: Periodically test the balance of your door. If you have a garage door
drawbar operator, use the release mechanism so you can operate the door by hand when do-
ing this test. Start with the door in the fully closed position. Lift the door to check its balance.
Adjust Extension spring(s), if door lifts by itself (hard to pull down) or if door is difficult to lift
(easy to pull down). DO NOT attempt to repair or adjust Torsion Springs yourself. To adjust
Extension spring(s), refer to your installation instructions and owner's manual. If in question
about any of the procedures, do not perform the work. Instead, have it adjusted by a trained
door systems technician.
3. Lubrication: The door should open and close smoothly. Ensure the door track rollers
14