Do It Yourself Service Chart
Problem: Power Nozzle does not operate or pick up
Cause:
Power Nozzle on/off switch is "O" off
Hose plugs not connected
Brush is not turning
Obstructed neck
Obstructed wand
Obstructed hose
Worn Brush
Circuit Breaker Tripped
Problem: Squeaky rollers on Power Nozzle
Apply liquid wax on axles of rollers.
Correction:
Move Power Nozzle on/off switch to "I" on.
Review instruction on attaching the Power
Nozzle, making sure all plugs are firmly
connected.
Make sure all electrical plugs are firmly
connected. Push reset button on back of
nozzle. If this does not work, call your local
FILTERQUEEN
®
Run a wire through opening.
Remove the hose from inlet and attach to the
exhaust port to blow out clogged debris.
Remove hose from inlet and attach to exhaust
port to blow out clogged debris.
Call your local FILTERQUEEN
for service.
Unplug cord and check for an obstruction. After
obstruction is cleared, push reset button on back
of nozzle. If this does not work, call you local
FILTERQUEEN
®