Heat & Glo TIARAI-BK-C Owner's Manual page 33

Direct vent room heater
Table of Contents

Advertisement

WING NUT
Figure 8.22
Slide temperature sensor switch/bracket
assembly onto the 10-32 screw located on the left
underside of the appliance. Secure the bracket assembly
with the wing nut provided.
Disconnect the two wire ends connected together on
the junction box. Connect female end to one side of
temperature sensor switch.
Connect one end of the black wire provided with the kit to
the remaining wire end on junction box.
Feed loose ends of the black and blue wires through the
orange grommet in fan housing.
BLACK
TEMPERATURE SENSOR SWITCH
Figure 8.23 Blower Wiring Diagram
VARIABLE SPEED CONTROL
JUNCTION BOX
BLACK
GROUND
BLACK
110 - 120 VAC
POWER SUPPLY
Heat & Glo • TIARA I-C • 7066-100 Rev. D • 12/11
Figure 8.24
Remove valve access cover from back of
appliance by removing the three screws indicated.
SPEED CONTROL
Figure 8.25
Remove the knob and lock nut from the speed
control. Install speed control onto access panel with stem
sticking out the pre-punched hole. Attach the lock nut tightly
and re-attach the knob on the stem.
Attach blue and black wires routed through orange grommet
in fan housing to the speed control. Re-install access panel.
WHITE
GREEN
3
SCREWS
LOCK NUT
AND STEM
BLOWER RECEPTACLE
BLOWER
33