Diagnostic Messages - champion spas 108 Owner's Manual

Table of Contents

Advertisement

d iag n o S T i C m E S S ag E S
Scroll message
NO COMM
The panel is not receiving communication from the system
---*F ---*C
Temperature unknown
HTR TOO
One of the water temp sensors has detected 118*F
HOT (OHH)
(47.8*C) in the heater and the spa is shut down.
WATR TOO
One of the water temp sensors has detected spa water
HOT (OHS)
110*F(43.3*C) and spa functions are disabled.
42*F TOO
A potential freeze condition has been detected or Aux
COLD
Freeze Switch has closed
102F SNSR
Temperature sensors MAY be out of sync by 2*F or 3*F
BALANCE
SNSR SYNC
Temperature sensors ARE out of sync . The Sensor Balance
is Poor . Fault has been established for at least 1 hour .
SNSR A
A temperature sensor or sensor circuit has failed
SNSR B
A temperature sensor or sensor circuit has failed
HTR FLOW
There may not be enough water flow through the heater to
carry the heat away from the heating element . Heater start-
LOSS (HFL)
up will begin again after 1 minute .
HTR FLOW
There IS NOT enough water flow through the heater to
carry the heat away from the heating element and the heater
FAIL (LF)
has been disabled . After the problem is resolved, you must
press any button to reset and begin heater start up .
HTR MAY BE
POSSIBLE dry heater, or not enough water in the heater
to start it . The spa is shut down 15 min . Press any button
DRY (dr)---
to reset the heater start-up .
WAIT
HTR DRY
There IS NOT enough water in the heater to start it . The
spa is shut down . After the problem has been resolved, you
must press any button to reset and restart heater start-up .
102T
Control System is in Test Mode
PRES BTTN
Some errors may require power to be removed and
TO RSET
restored . A reset message may appear with other messages
HOT FALT
A pump appears to be stuck ON, a serious condition that
COULD result in overheated spa water
*Please contact your Dealer for the following messages: MEM FAIL, MEM RSET, CNFG FAIL, STUK PUMP*
Note: Start-up Procedures – page 13 in current Champion OM
FloW rElaTEd ChECKS -
Check for low water level, suction flow restrictions, closed valves, trapped air, too many closed jets and pump prime .
On some systems even when the spa is shut down, some equipment may occasionally turn on to continue monitoring
temperature or if freeze protection is needed .
All messages may not appear on your panel display .
20
C h a mp i o n Spa s ®
OWN E R 'S M A N UA L
meaning
action required
Call for Service
After pump has run for 1 minute, the
temperature will be displayed
DO NOT ENTER THE WATER .
Remove the spa cover and allow water
to cool . Once the heater has cooled,
reset by pushing any button . If spa
does not reset, shut off the power to
the spa and call your dealer or service
organization .
DO NOT ENTER THE WATER .
Remove the spa cover and allow water
to cool . At 107˚F/42˚C, the spa should
automatically reset . If spa does not
reset, shut off the power to the spa and
call your dealer or service organization .
All pumps are activated automatically
& stay on at least 4 minutes after
potential freeze condition has ended
or aux freeze switch opens . This is
an operational message, not an error
indication.
Call for Service
Call for Service
Call for Service
Call for Service
See FLOW RELATED CHECKS
below
See FLOW RELATED CHECKS
below
See FLOW RELATED CHECKS
below
See FLOW RELATED CHECKS
below
Call for Service
Press button to reset
Call for Service