Factory
Installed
Neutral
(Pigtail)
Incoming
Ground (Green)
Incoming
Power (Black
)
!

Electrical Spa Wiring Connection instructions

!
Due to the risk of damaging the PC Board, the equipment and the GFCI tripping,
never, under any circumstances, should you connect power to the neutral terminal.
1 . Identify the TB1 terminal block, located inside the spa power pack on the left side .
2 . Connect the 8 AWG, WHITE wire, from the GFCI 50 amp breaker,to the WHITE "NEU"
terminal on TB1 .
3 . Connect the 8 AWG, BLACK wire, from the GFCI 50 amp breaker, to the BLACK "HOT"
terminal on TB1 .
4 . Connect the 8 AWG, RED wire, from the GFCI 50 amp breaker, to the RED "HOT"
terminal on TB1 .
5 . Connect the 8 AWG, GREEN wire, from the GFCI 50 amp breaker, to the GREEN
"GROUND" location on the "BONDING LUGS" terminal .
6 . At least two additional lugs marked "BONDING LUGS" are provided on the external surface
of one of the bonded components metal enclosures . To reduce the risk of electrical shock,
connect the local common bonding grid in the area of the hot tub or spa to these terminals
with an insulated or bare copper conductor not smaller than No . 6 AWG .
7 . All field-installed metal components such as rail, ladders, drains or other similar hardware
within 10 ft (3m) of the spa or hot tub shall be bonded to the equipment grounding bus with
copper conductors not smaller than No . 6 AWG .
!
8 . Replace the control box cover and securely tighten the fastening screws . Close and secure the
equipment compartment panel .
Always use copper wire only (3 wire with ground; 8 gauge under 50ft, 6 gauge over
!
50ft) . The electrical supply for this product must include a suitable rated switch or
circuit breaker to open all ungrounded supply conductors to comply with Section
422 .20 of the National Electrical Code ANSI/NEPA 70-1987 . The disconnecting
!
means must be readily accessible to the tub occupant but installed at least 5 feet (1 .5m)
from tub water
!
Please review the back of the spa pack cover, located in the spa equipment bay, for a
complete spa equipment wiring diagram .
b oTTom V i E W
oF b rE a K Er
Power to Spa
Neutral to Spa
Ground to Spa
Outgoing Power to Spa
Outgoing Neutral to Spa
Incoming Power (Black or Red)