Controls; Vaillant Controls And Accessories; External Electrical Controls; Connection Details For External Time Switches - Vaillant ecoTEC plus 612 Instructions For Installation And Servicing

Wall hung room sealed fan assisted condensing boiler
Table of Contents

Advertisement

4 Boiler installation sequence

4.15 Controls

4.15.1

Vaillant controls and accessories

Controller
VRC 400 (1-circuit controller, weather-controlled)
VRT 360 (room temperature controller)
Available from 10-01-2006
VRT 360f (room temperature controller)
VRT 230 (room temperature controller)
timeSWITCH 140 (timer)
timeSWITCH 130 (timer)
VRT 30 (room thermostat)
VRT 50 (room thermostat)
Telecommunication
vrnetDIALOG 830 (Int)
vrnetDIALOG 860/2 (Int)
Accessories
VR 65 control centre for UK cylinder installation (eBUS)
vrDIALOG 810/2
Table 4.1 Vaillant controls and accessories

4.15.2 External electrical controls

The boiler terminals 3, 4 and 5 are for connecting exter-
nal electrical controls such as a time switch and/or
room thermostat. Terminals 3 and 4 are linked together
when the boiler is supplied. If external controls are used,
this link must be removed, and the controls connected
across terminals 3 and 4. Terminal 5 is an additional
neutral connection for external neutrals such as from
the anticipator of a room thermostat.

4.15.3 Connection details for external time switches

and boiler terminal strip

20 VDC
7
8
9
N
L
3 A FUSE
MAINS
SUPPLY
230 V
50 Hz
Fig. 4.18 Connection details for time switches
28
(DO NOT USE 7 , 8, 9 IN UK!)
L N
3
4
5
ROOM
SWITCH
THERMOSTAT
CONTACTS
L
CLOCK
N
N
Item no.
Connection
00 2001 0843
Installation in electronics box (plug-and-play)
00 2001 0842
Wall-mounted, 2-wire bus
00 2001 8258
Wireless controller, receiver wall-mounted
00 2001 0841
Wall-mounted, 3-wire connection to terminals 3-4-5
306 760
Installation in electronics box (plug-and-play)
306 759
Installation in electronics box (plug-and-play)
300 637
Wall-mounted, 3-wire connection to terminals 3-4-5
00 2001 8265
Wall-mounted, 2-wire bus
Item no.
Connection
00 2000 3988
GSM/GPRS, installation in electronics box (plug-and-play)
00 2000 3984
Wall-mounted, GSM/GPRS, up to 16 appliances
Item no.
Connection
307 215
System solution for UK cylinder connection
00 2002 3370
Diagnostic software
If a room thermostat is to be connected in addition to a
time switch the wire between the time switch "ON" termi-
nal and boiler terminal 4 should be broken by the contacts
of the room thermostat (see schematic layout, fig. 4.18).

4.15.4 Vaillant optional plug in timer accessories

Refer to the instructions supplied with the optional
accessories for connection details. Upon completion of
all electrical connections refit the terminal box cover by
pushing into place. The cover is secured by two locking
clips.
4.15.5 Connection details using the VR 65 Control
Center
The VR 65 Control Center is an eBUS system component.
In a storage unit installation, it is responsible for the
communication between the storage unit, the ecoTEC
plus system boilers and external 2- or 3-way-valves.
Connect the VR 65 Controll Center as described in the
enclosed manual.

4.16 Thermostatic radiator valves

The boiler has a built in automatic by-pass valve making
it ideal for use in systems with thermostatic radiator
valves (no separate system by-pass is required). For
optimum fuel economy where TRV's are used they must
be used in conjunction with a boiler control interlock. A
programmable room thermostat or separate timer and
room thermostat will ensure complete boiler shut down
when the heating demand is satisfied. (The radiator in
the room containing the room thermostat should not be
fitted with a TRV).