3.6

Flue pipe

Danger!
Vaillant appliances are certified only for use
with genuine Vaillant flue pipes. Only use genu-
ine Vaillant flue pipes. Malfunctions can occur if
you use other accessories. These may result in
damage and injury. You will find a list of genuine
flue pipes in the Vaillant installation manual for
flue pipes.
The CE mark is valid only if the appliance is
operated with Vaillant flue pipes.

3.6.1 Standard 100 mm flue system

Fig. 3.4 Art. No. 303 933
A standard 100 mm flue system (Art. No. 303 933) is
available. Refer to flue system installation instructions
for full details.
Flue extensions are available to extend this length up to
8 m. Both 90° bends and 45° elbows are also available
to increase siting flexibility.
Fig. 3.5 Art. No. 0020060570
Instructions for installation and servicing ecoTEC / 839592_09
General requirements 3

3.6.2 Optional 125 mm flue system

A concentric flue system of 125 mm outside diameter is
available and can be used to achieve flue lengths up to
25 m.
A vertical flue system is also available. Refer to flue sys-
tem installation instructions for full details.
Fig. 3.6 Art. No. 303 209
Fig. 3.7 Art. No. 303 200
3.7

Flue termination

The following details refer to both flue systems.
a. The terminal must be located where the combustible
substances can escape freely at all times.
b. A plume of water vapour will sometimes be visible
from the flue terminal. Positions where this could be
a nuisance should be avoided.
c. If the terminal is fitted less than 2 m above a balco-
ny, above ground or above a flat roof to which peo-
ple have access then a suitable terminal guard must
be provided and fitted (made by Tower Flue
Components, Tonbridge, TN9 1TB, Model K3, plastic
coated).