Furnace Specifications - Amana AMH95 Series Technical Manual

40" 95% gas furnace
Hide thumbs Also See for AMH95 Series:
Table of Contents

Advertisement

FURNACE SPECIFICATIONS

MODEL
Btuh
Input (US)
Output (US)
Input (CAN)
Output (CAN)
A.F.U.E.
Rated External Static (" w.c.)
Temperature Rise (°F)
ID Blower Pressure Switch Trip Point (" w.c.)
Front Cover Pressure Switch Trip Point (" w.c.)
Blower Wheel (D" x W")
Blower Horsepower
Blower Speeds
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
Transformer (VA)
Primary Limit Setting (°F)
Auxiliary Limit Setting (°F)
Rollout Limit Setting (°F)
Fan Delay On Heating
(3)
Off Heating
Fan Delay On Cooling
Off Cooling
Gas Supply Pressure (Natural/Propane) ("w.c.)
Manifold Pressure (Natural/Propane) ("w.c.)
Orifice Size (Natural/Propane)
Number of Burners
Vent Connector Diameter (inches)
Combustion Air Connector Diameter (inches)
Shipping Weight (lbs.)
(1)
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: May use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
(3)
Off Heating - this fan delay timing is adjustable (100 and 150 seconds). Furnaces are shipped with 150 second off delay.
(4)
See Installation Instructions for appropriate vent diameter, length and number of elbows.
(5)
See Installation Instructions for appropriate combustion air pipe diameter, length and number of elbows.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in
accordance with all national and/or local electrical codes. Use copper wire only.
1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation.
2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only
be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers method or in accordance with the "A.S.H.R.A.E.
GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal
to or less than the heating capacity. Output based on D.O.E. test procedures.
4. Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
AMH95
0453BXA*
46,000
44,400
46,000
44,400
95.0%
.20 - .50
35 - 65
-1.10
-0.37
10 x 8
1/3
4
1200
115-60-1
(1)
9.4
(2)
15.0
40
150
150
200
30 secs.
150 secs.
6 sec.
45 secs.
7 / 11
3.5 / 10
43 / 55
2
(4)
2
(5)
2
132
AMH95
AMH95
0703BXA*
0704CXA*
0904CXA*
69,000
69,000
66,400
66,900
69,000
69,000
66,400
66,900
95.0%
95.0%
.20 - .50
.20 - .50
30 - 60
35 - 65
-0.95
-1.10
-0.37
-0.37
10 x 8
10 x 10
1/3
1/2
4
4
1200
1600
115-60-1
115-60-1
9.4
13.8
15.0
15.0
40
40
160
160
150
150
200
200
30 secs.
30 secs.
150 secs.
150 secs.
150 secs.
6 sec.
6 sec.
45 secs.
45 secs.
7 / 11
7 / 11
3.5 / 10
3.5 / 10
43 / 55
43 / 55
3
3
2
2
2
2
135
136
AMH95
AMH95
AMH95
AMH95
0905DXA*
1155DXA*
92,000
92,000
115,000
89,000
88,400
110,500
92,000
92,000
115,000
89,000
89,400
110,500
95.0%
95.0%
.20 - .50
.20 - .50
.20 - .50
30 - 60
35 - 65
35 - 65
-1.20
-1.10
-0.60
-0.37
10 x 10
11 x 10
11 x 10
1/2
3/4
4
4
1600
2000
115-60-1
115-60-1
115-60-1
13.8
13.2
15.0
15.0
40
40
150
160
150
150
200
200
30 secs.
30 secs.
30 secs.
150 secs.
150 secs.
6 sec.
6 sec.
45 secs.
45 secs.
45 secs.
7 / 11
7 / 11
3.5 / 10
3.5 / 10
3.5 / 10
43 / 55
43 / 55
43 / 55
4
4
2
2
2
2
158
172
95.0%
-1.10
-0.60
3/4
4
2000
13.2
15.0
40
160
160
200
6 sec.
7 / 11
5
2
2
175
11