LOW
HIGH
PRESSURE
PRESSURE
GAUGE MANIFOLD
TO
HFC−410A
DRUM
SERVICE PORT CAP
SERVICE PORT
CORE
OPEN TO BOTH
INDOOR AND
OUTDOOR UNITS
TO INDOOR
UNIT
TO OUTDOOR UNIT
Figure 5. Angle−Type Service Valve
(Back−Seated Opened)
1. Remove stem cap with a wrench.
2. Use a service wrench with a hex−head extension
(3/16" for liquid-line valve sizes and 5/16" for
suction-line valve sizes) to back the stem out
counterclockwise as far as it will go.
3. Replace the stem cap and tighten as follows:
S
With Torque Wrench: Tighten finger tight and then
tighten per table 1.
S
Without Torque Wrench: Finger tighten and use an
appropriately sized wrench to turn an additional
1/12 turn clockwise as illustrated in figure 2.
To Access Ball−Type Service Port:
A service port cap protects the service port core from
contamination and serves as the primary leak seal.
1. Remove service port cap with an appropriately sized
wrench.
2. Connect gauge to the service port.
3. When testing is completed, replace service port cap and
tighten as follows:
506044−01 06/08
LIQUID LINE
SERVICE VALVE
FILTER
DRIER
Figure 4. Typical Manifold Gauge Connection Setup
SERVICE PORT
(VALVE STEM SHOWN OPEN)
INSERT HEX WRENCH HERE
STEM CAP
OUTDOOR UNIT
OUTDOOR
COIL
SUCTION LINE
SERVICE VALVE
COMPRESSOR
S
With Torque Wrench: Finger tighten and then
tighten per table 1.
S
Without Torque Wrench: Finger tighten and use an
appropriately sized wrench to turn an additional
1/6 turn clockwise as illustrated in figure 2.
To Open and Close Ball−Type Service Valve:
A valve stem cap protects the valve stem from
contamination and assures a leak−free seal.
1. Remove stem cap with a wrench.
2. Use an appropriately sized wrench to open. To open
valve, rotate stem counterclockwise 90°. To close
rotate stem clockwise 90°.
3. Replace the stem cap and tighten as follows:
S
With Torque Wrench: Finger tighten and then
tighten per table 1.
S
Without Torque Wrench: Finger tighten and use an
appropriately sized to wrench turn an additional
1/12 turn clockwise as illustrated in figure 2.
OPEN TO LINE SET WHEN VALVE IS
CLOSED, TO BOTH LINE SET AND
UNIT WHEN VALVE IS OPEN.
TO OPEN ROTATE STEM
COUNTERCLOCKWISE
90°.
TO CLOSE ROTATE
STEM CLOCKWISE 90°.
PORT CORE
SERVICE PORT
TO OUTDOOR UNIT
Figure 6. Ball−Type Service Valve
Page 4
(Uncased Coil Shown)
TXV
TO INDOOR UNIT
BALL
(SHOWN
CLOSED)
SERVICE
PORT
SERVICE
CAP
STEM
VALVE
STEM
CAP