Amana 10759833 Installation Instructions Manual page 30

Two-stage variable speed
Table of Contents

Advertisement

Startup Procedure and Adjustment
8 7
4 3 2 1
Cooling
Speed
Tap A
O
O
F
F
F
F
8 7
4 3 2 1
Cooling
Speed
Tap B
O
O
F
N
F
8 7
4 3 2 1
Cooling
Speed
Tap C
O
O
N
F
F
8 7
4 3 2 1
*
Cooling
Speed
Tap D
O
O
N
N
Cooling Speed Taps
*
(
indicates factory setting)
8 7
4 3 2 1
*
Normal
O
O
F
F
F
F
8 7
4 3 2 1
+ (Plus)
Adjust
O
O
F
N
F
8 7
4 3 2 1
- (Minus)
Adjust
O
O
N
F
F
Adjust Taps
*
(
indicates factory setting)
8 7
4 3 2 1
Heating
Speed
Tap A
O
O
F
F
F
F
8 7
4 3 2 1
*
Heating
Speed
Tap B
O
O
F
N
F
8 7
4 3 2 1
Heating
Speed
Tap C
O
O
N
F
F
8 7
4 3 2 1
Heating
Speed
Tap D
O
O
N
N
Heating Speed Taps
*
(
indicates factory setting)
Adjust Blower Heat Off Delay
The integrated control module provides a selectable heat
off delay function. The heat off delay period may be set to
60, 90, 120, 180 seconds using the DIP switches or jumper
provided on the control module. The delay is factory
shipped at 90 seconds but may be changed to suit the
installation requirements and/or homeowner preference.
Refer to the following figures for switch positions and
corresponding delay times.
ON
ON
ON
OFF
OFF
ON
OFF
OFF
(* indicates factory setting)
Heat Off Delay Switches
30
30
Heat Off
3
Delay
2
60 Seconds
1
*
3
Heat Off
Delay
2
90 Seconds
1
3
Heat Off
Delay
2
120 Seconds
1
3
Heat Off
Delay
2
180 Seconds
1
Heat Off Delay

Advertisement

Table of Contents
loading

Table of Contents