Savio 20/1 MFS User Manual page 16

Wall hung fan flue room sealed gas combination boiler
Table of Contents

Advertisement

installation
Mounting operations
--- Insert the exhaust pipe into the suction pipe so that the wind---
resistant terminal contacts the rim which is located on the inside
of the suction pipe;
--- introduce the pipe assembly, together with wind---resistant ter-
minal, into the hole you have drilled in the wall.
A 20 mm (0,78 ins) length of the suction pipe must protrude from
the wall;
--- mount the wall gaskets on the pipe;
--- position the gaskets so when the pipe is pulled back they make
good seal against the wall;
--- insert the pipe support;
--- insert the suction pipe on the tightening band;
--- install the gasket which seals the elbow to the duct by placing
the larger internal diameter of the gasket on the air suction pipe;
--- place the gasket on the surface of the appliance;
--- install the elbow on the support; be sure that the following condi-
tions are met:
make sure that the flue exhaust pipe is firmly inserted into the
elbow;
be sure that a distance of 6 mm (0,23 ins) has been left between
the suction pipe and the elbow.
The purpose of this space is to allow the elbow to be removed
for maintenance after the pipe has been enclosed in the wall.
Therefore, never push the suction pipe into the elbow;
--- use the screws to attach the elbow to the surface of the
appliance;
--- use the gasket you previously installed to seal the connection
between the elbow and the duct;
--- use the gasket tightening band with springs and screws to
tighten the gasket;
--- make two ø3,7 mm (0,14 ins) holes; one on the elbow and the
other on the intake pipe at the same level as the holes on the
gasket tightening band;
--- use the screws supplied with the kit to connect the elbow, the
band and the pipe together.
14
rev. 17.09.93
28
29
28
20
19
24
28
25
6 mm
(0,22 ins)
27
27
26
23
19
19
29
20 mm
(0,78 ins)
24
28
19
30
21

Hide quick links: