Wall hung fan flue, room sealed gas boiler (48 pages)
Summary of Contents for Savio Savio
Page 1
• If you can not reach your gas supplier call the re department. — Installation and service must be performed by a quali ed installer, service agency or the gas supplier. SAVIO HEAT ONLY MANUAL...
Page 2
CSA 4.9 and is CSA compliant. This SAVIO Heating Only boiler has a 2 year warranty on the boiler, and 10 years on the heat exchanger a copy of which is provided with the boiler. Please be sure to return the warranty registration card as the warranty will be void without your boiler’s serial numbers (located on...
Room Thermostat Connection 12.3 Relay Panel Control Connection 12.4 Zone Valve Microswitch Connection 12.5 Circulator Sizing Circ. Cap. as a Function of Flow Rate 13.1 Expansion Vessel 13.2 Piping 26-28 Primary-Secondary Piping 14.1 Primary-Secondary with Zone Valves 14.2 SAVIO HEAT ONLY MANUAL...
Emptying the C.h. System 17.3 Cleaning the Primary Heat Exch. 17.4 Checking the Pressuris. in C.h. Vess. 17.5 Cleanig the Burner 17.6 Checking the Flue 17.7 Visual Inspection of Appliance 17.8 Gas Pressures and Soundness 17.9 Installer Notes SAVIO HEAT ONLY MANUAL...
Page 5
Installation and service must be performed by a quali ed installer, ser- vice agency or the gas supplier. DANGER Caution: Do not store or use ammable materials, chemicals or ammable liquids, especially gasoline, in the vicinity of this heating appliance. SAVIO HEAT ONLY MANUAL...
Page 6
If any of the symptoms of CO occur, or if any of the signs of carbon monoxide are present, VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SER- VICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT. ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR SAVIO HEAT ONLY BOILER. SAVIO HEAT ONLY MANUAL...
- B149 Installation Codes E. ANSI/ASME - CSD-1 The above codes are available from: National Fire Protection Association (NFPA) CSA International Battery March Park 8501 E. Pleasant Valley Road Quincy, Massachusetts, 02269 Cleveland, OH 44134-5575 http://www.nfpa.org http://www.csa-international.org SAVIO HEAT ONLY MANUAL...
General Information The SAVIO Heat Only is a high ef ciency, non-condensing, wall mounted gas boiler which pro- vides central heat. The boiler features a gas valve which modulates the energy input from 49,476 BTU/h to 122,837 BTU/h. The boiler is shipped fully assembled with the components listed on page 10.
Page 9
Power consumption 2.25/4 Coaxial 3.25/5 FLUE GAS FIGURES Twin split pipes 3.25/3.25 Nominal heat ow rate 122.8 2.5% 7.2% (0/2000ft) 16.5% 8.1% Nominal heat ow rate 116.7 (2000/4500ft) Min Exhaust temperature °F Max Exhaust temperature °F SAVIO HEAT ONLY MANUAL...
28 Pressure reducing automatic ll valve 13 Safety thermostat 29 Back ow preventer 14 Modulation operator 30 Gas supply line cock 15 Gas valve outlet pres. Test point 31 Water supply inlet cock 16 Gas valve inlet pres. Test point 10 SAVIO HEAT ONLY MANUAL...
Internal Piping & Parts List Note: Pressure Relief Valves (#19) should be piped to a drain or to the oor as lose as pos- sible to a drain. SAVIO HEAT ONLY MANUAL...
Electric Diagrams Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause im- proper and dangerous operation. Verify proper operation after servicing 12 SAVIO HEAT ONLY MANUAL...
Air Opening 0 to 12" Figure 6.2 When choosing an installation location insure the exhaust and intake pipes comply with NFPA 54. The drawing on the next page illustrates the restrictions on exhaust locations. SAVIO HEAT ONLY MANUAL...
The vent should not be situated so that the ue gases are directed towards brickwork,siding, or other construction, in such a manner that may cause damage from heat or condensate from the ue gases 14 SAVIO HEAT ONLY MANUAL...
If you are using a separate pipe system drill holes marked B and C (ø 3.25”) shown below as well as on the paper template. Remove paper template and hang boiler on bracket. Figure 8.1 SAVIO HEAT ONLY MANUAL...
Venting The SAVIO is a mechanical draft, side wall vented boiler. There are two ue options available - separate and coaxial. The coaxial option has one con guration shown on the next page. The separate option has two possible con gurations shown on the following pages.
Connect exhaust (inner) pipe to concentric elbow. • Connect intake (outer) pipe to concentric elbow. • Secure elbow to boiler using gasket and four screws provided. • Secure end cap on the intake pipe outside the house. SAVIO HEAT ONLY MANUAL...
Page 18
Attach each collar to the boiler with the gasket and screws provided. • Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow (as shown in the diagram). • Secure end cap on the intake and exhaust pipe outside the house. 18 SAVIO HEAT ONLY MANUAL...
Page 19
Slide one rubber wall trim piece on the pipe from inside and one from outside. • Attach each collar to the boiler with the gasket and screws provided. • Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow. SAVIO HEAT ONLY MANUAL...
Pipe Connections The SAVIO boiler is supplied with a 3/4” stainless steel gas pipe (A in gure 10.1), 2 - 3/4” cop- per pipe (C,D in gure 10.1), located in a plastic bag in the boiler package. Figure 10.1 Stainless steel gas pipe C.h.
Note: Do not connect live wires to Power supply thermostat terminals 1-3. terminal block External controls terminal block Figure 12.5 • Connect the earth wire(yellow/green). Boiler must be wired directly to earth ground on breaker panel. 22 SAVIO HEAT ONLY MANUAL...
Figure 12.8 • Connect the dry contact switch to termi- • When connecting any type of relay con- nals 1 and 3 shown in Fig. 12.9. trol, the jumper J in Fig. 12.8 must be re- moved. SAVIO HEAT ONLY MANUAL...
To the external control device To the fused spur isolation switch Figure 12.12 • Lock the cords in place with the exible cord clamps. • Replace the control panel reversing the steps on page 22. 24 SAVIO HEAT ONLY MANUAL...
23 ft at most. For greater differences, increase the pre-load pressure in the C.h. expansion vessel (17 on page 10) and the system when cold, by 0.1 bar for additional 3.3 ft. For systems with volumes greater than 154l, an additional expansion vessel must be provided. SAVIO HEAT ONLY MANUAL...
All external piping components are to be supplied by the installer. It is very important to use an hydraulic separator before secondary circulators. Hydraulic Separator Min. Spacing 12" Max. Spacing 4x Primary Pipe Secondary Circulator Dia. Typ. Secondary Loops 26 SAVIO HEAT ONLY MANUAL...
Page 27
All external piping components are to be supplied by the installer. It is very important to use an hydraulic separator before secondary circulators. Supply Lines to System Zone Valve zone zone zone Secondary Circulator valve valve valve Return Lines from System Hydraulic Separator SAVIO HEAT ONLY MANUAL...
Manifold Piping with Zone Valves or Circulators (shown conn. to radiators): All external piping components are to be supplied by the installer. Return Water Temperature Gauge By-pass Valve Shut Off Valve System Return Manifold System Supply Manifold (with zone valves or circulators 28 SAVIO HEAT ONLY MANUAL...
D will appear. To reset the boiler turn the knob B ( gure 15.3) on the 0 position and then press and release the boiler reset button C (Fig. 15.3). SAVIO HEAT ONLY MANUAL...
Switch on the boiler. points must be sealed. • Check the maximum gas pressure and com- pare the value on the gauge with the value indicated in the Section 2 on page 9 (gas pressures at the burner). 30 SAVIO HEAT ONLY MANUAL...
(D on Figure 15.3). To reset the boiler turn the knob B ( gure 15.3) on the 0 position and then press and release the boiler reset button (C on Figure 15.3). SAVIO HEAT ONLY MANUAL...
Adjust the gas pressure at the burner to the value according to the useful c.h. output wanted (Tab. 15.1). • Reassemble the service panel. • Close the gas valve outlet pressure test point 15 ( gure 15.5). • Reassemble the front pannel of the case. 32 SAVIO HEAT ONLY MANUAL...
All the labels supplied with the boiler are numbered for reference. According to Figure 15.10 place all the labels on the boiler. Use label numbered as 1 (already installed in the front panel) to begin the placement in the correct way. SAVIO HEAT ONLY MANUAL...
(included with the conversion kit) indicating the type of gas, and the gas pres- sures to which the appliance has been set. • Reassemble the front and side panels of the case. SAVIO HEAT ONLY MANUAL...
Open the central heating drain cock (F in Fig. 17.3). • Empty the c.h. system. • Close the central heating drain cock (F in Fig. 17.3). • Open the pressure reducing automatic ll valve (28 on Section 4) Figure 17.3 36 SAVIO HEAT ONLY MANUAL...
Visually inspect all water joints, seals and connections for any evidence of leakage and re- tighten, grease or replace them as necessary. 17.9 Gas pressures and soundness: Check appliance for gas soundness. Recheck operational pressures and adjust as necessary as described in Section 15.4 page 31 of this manual. SAVIO HEAT ONLY MANUAL...