Access Codes; User Code Attributes - DCS PowerSeries System Keypads User Manual

Security system dsc
Table of Contents

Advertisement

For systems using multiple partitions/areas, access codes can be assigned to specific or multiple partitions/areas.
Please contact your alarm company for details.
The minimum number of variations of access codes (key) is 27027 when 37, 6-digit user codes are used. For SIA
Installations, duplicate or duress codes derived from user codes +/- 1 digit are not allowed.
The access codes have programmable attributes which allow zone bypassing, remote access using the
ESCORT5580TC or one-time use activation.

Access Codes

,
[
][5][Master Code] (when disarmed)
,
The [
][5] User's Programming command is used to program additional access codes.
User Codes (Access Codes 1-32)
Master Code (Access Code 40)
Supervisor Codes (Access Codes 41 & 42)
Programming section. However, these codes can only program additional codes which have equal or lesser
attributes. Once programmed, the Supervisor Codes receive the Master Code's a rib tes. These attributes are
changeable.
Duress Codes (Access Codes 33 & 34)
Duress Reporting Code whenever the code is entered to perform any func on on the system.
NOTE: Duress codes are not valid when entering [
NOTE: No codes can be programmed as a duplicate of another code
NOTE: Duress codes cannot be programmed as a duplicate or as a Code + 1".

User Code Attributes

1. The default attributes of a new code will be the at ibutes of the code used to enter
code or an existing code being programmed.
2. System Master (Code 40) has Partition Access
NOTE: These attributes are not changeable
Inherent Attributes (all codes ex ep installer and maintenance)
- Any Access Code with Partition Access enabled will be valid for arming and disarming that partition.
Arm / Disarm
,
Command Outputs ([
Access Code with Partition Acc ss will be valid for performing the [
tion.
Programmable Attributes ([
1. For Future Use
2. For Future Use
3. Zone Bypassing Enabled
4. ESCORT Access
5. Downlook Remote Trigger to Phone Number 1
6. Downlook Remote Trigger to Phone Number 2
7. Bell Squawk upon Arming/Disarming
8. One Time Use Code
NOTE: Attributes 5 and 6 cannot be enabled on the same access code.
- The Master Code can only be changed by the Installer, if programmed.
- These codes are always valid when entering the
- Duress codes 33 and 34 are standa d User Codes that will transmit the
,
,
][7][1], [
][7][2], [
][7][3], and [
,
][5][Master/Supervisor Code][9][Code])
,
,
,
][5], [
][6] or [
][8] sections.
r all partitions, as well as Attributes 3-4 ON by default.
,
- If these outputs require Access Code entry, any
][7][4])
,
][7][1-4][Access Code] functions on that parti-
12
User Code
whether it is a new

Hide quick links:

Advertisement

Table of Contents
loading