SAFETY INSTRUCTIONS FOR SERVICE PERSONNEL
WARNING: WHEN USING EQUIPMENT CONNECTED TO THE TELEPHONE NETWORK, THERE ARE BASIC SAFETY
INSTRUCTIONS THAT SHOULD ALWAYS BE FOLLOWED. REFER TO THE SAFETY INSTRUCTIONS PROVIDED WITH THIS
PRODUCT; SAVE THEM FOR FUTURE REFERENCE. INSTRUCT THE END-USER REGARDING THE SAFETY PRECAUTIONS
THAT SHALL BE OBSERVED WHEN OPERATING THIS EQUIPMENT.
Selecting a Suitable Location for the Alarm Controller
Use the following list as a guide to find a suitable place for this equipment:
•
Locate the control panel near a telephone socket and a power outlet.
•
Select a place that is free from vibration and shocks.
•
Place the alarm controller on a flat, stable surface and follow the installation instructions.
Do NOT locate this product where persons will walk on the secondary circuit cable(s).
Do NOT connect the alarm controller to electrical outlets on the same circuit as large appliances.
Do NOT select a place that exposes your alarm controller to direct sunlight, excessive heat, moisture, vapors, chemicals or dust.
Do NOT install this equipment near water. (e.g., bath tub, wash bowl, kitchen/laundry sink, in a wet basement, or near swimming pools, etc.).
Do NOT install this equipment and its accessories in areas where there is a risk of explosion.
Do NOT connect this alarm controller to electrical outlets controlled by wall switches or automatic timers.
AVOID sources of radio interference.
AVOID setting up the equipment near heaters, air conditioners, ventilators, and/or refrigerators.
AVOID locating this equipment close to or on top of large metal objects (e.g., metal wall studs).
Safety Precautions Required During Installation
•
NEVER install this equipment and/or telephone wiring during a lightning storm.
•
NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
•
Ensure that cables are positioned so that accidents can not occur. Connected cables must not be subject to excessive mechanical strain.
•
For Direct Plug-in versions, use the transformer supplied with the device.
THIS EQUIPMENT HAS NO MAINS ON/OFF SWITCH. THE PLUG OF THE DIRECT PLUG-IN POWER SUPPLY IS INTENDED TO
SERVE AS THE DISCONNECTING DEVICE IF THE EQUIPMENT MUST BE QUICKLY DISCONNECTED. IT IS IMPERATIVE
THAT ACCESS TO THE MAINS PLUG AND ASSOCIATED MAINS SOCKET/OUTLET, IS NEVER OBSTRUCTED.
The PC9155 Alarm System shall be installed and used within an
environment that provides the pollution degree max 2 and over-
voltages category II NON-HAZARDOUS LOCATIONS, indoor only.
The equipment is DIRECT PLUG-IN (external transformer) or PER-
MANENTLY CONNECTED (See Figure 2-3: Mounting & Wiring
Details) and is designed to be installed, serviced and/or repaired by
service persons only; [service person is defined as a person having
the appropriate technical training and experience necessary to be
aware of hazards to which that person may be exposed in
performing a task and of measures to minimize the risks to that
person or other persons]. There are no parts replaceable by the
end-user within this equipment. The wiring (cables) used for
installation of the Alarm System and accessories, shall be insulated
with PVC, TFE, PTFE, FEP, Neoprene or Polyamide.
The power supply must be Class II, FAIL SAFE with double or reinforced insulation between the PRIMARY and SECONDARY circuit/ENCLO-
SURE and be an approved type acceptable to the local authorities. All national wiring rules shall be observed.
WARNING
(Direct plug-in versions only)
IMPORTANT NOTE!
(a) The equipment enclosure must be secured to the building
structure before operation.
(b) Internal wiring must be routed in a manner that prevents:
- Excessive strain or loosening of wire on terminal connections;
- Damage of conductor insulation
(c) Disposal of used batteries shall be made in accordance with
local waste recovery and recycling regulations.
(d) Before servicing, DISCONNECT the power and telephone
connection.
(e) DO NOT route any wiring over circuit boards.
(f) It is the installer's responsibility to ensure that a readily accessi-
ble disconnect device is incorporated in the building for permanently
connected installations.