Table of Contents

Advertisement

QuickServer Start-up Guide
PS-QS-1010/1011, PS-QS-1510/1511
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after August 2012
Kernel Version:
6.04
Document Revision: 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QuickServer PS-QS-1010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FieldServer QuickServer PS-QS-1010

  • Page 1 QuickServer Start-up Guide PS-QS-1010/1011, PS-QS-1510/1511 APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after August 2012 Kernel Version: 6.04 Document Revision: 11...
  • Page 2: Table Of Contents

    B.1. Communicating with the QuickServer over the Network ................. 23 Appendix B.2. Technical support.............................. 23 ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call Appendix B.3. Notes Regarding Subnets and Subnet Masks ....................23 +1 661.716.5100...
  • Page 3 Appendix D.3. QuickServer FS-QS-101X DCC ........................... 27 Appendix D.4. Compliance with UL Regulations ........................27 Appendix D.5. Address DIP Switch Settings ..........................28 Appendix D.6. Baud DIP Switch Settings ..........................30 ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 4: Supplied Equipment

    1 LonWorks is a registered trademark of Echelon Corporation Metasys is a registered trademark of Johnson Controls Inc. BACnet is a registered trademark of ASHRAE ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 5: Mounting

    3 . 1 . 1 D i m e n s i o n D r a w i n g PS - QS - 1 0 10/1510 - XXXX R1 Port R2 Port ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 6 3 . 1 . 2 D i m e n s i o n D r a w i n g PS - QS - 1 011/1511 - XXXX LonWorks Port R2 Port ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 7: Specifications

    This device may not cause harmful interference This device must accept any interference received, including interference that may cause undesired operation. Specifications subject to change without notice ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 8 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense. Modifications not expressly approved by FieldServer could void the user's authority to operate the equipment under FCC rules”...
  • Page 9: Installing The Quickserver

    To commission the QuickServer LonWorks port, insert a small screwdriver in the commissioning hole on the face of the QuickServer’s enclosure to access the Service Pin. See the instructions on the QuickServer as to which way to toggle the screwdriver during commissioning. ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 10 The S0 - S3 DIP switch selection is read directly into a Data Array. This Data_Array value can be used for customized operations such as configuration selection. ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 11: Operation

    The Default IP Address of the QuickServer is 192.168.2.X, Subnet Mask is 255.255.255.0. If the PC and the QuickServer are on different IP Networks, assign a Static IP Address to the PC on the 192.168.2.X network. ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 12: Use The Fieldserver Web Gui To Connect To The Quickserver

    Install the Discovery tool from the USB drive or get it from our website http://fieldserver.com/techsupport/utility/utility.php Use the Discovery tool to find the QuickServer, and launch the Web GUI from the Discovery tool ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 13: Set Ip Address Of The Quickserver

    If necessary, change the IP Gateway (Default Gateway field) Type in a new IP Gateway Note: If the FieldServer is connected to a router, the IP Gateway of the FieldServer should be set to the IP address of the router that it is connected to Click Update IP Settings, then click on the System Restart to restart the Gateway and activate the new IP address.
  • Page 14: Configuring The Quickserver

    C h a n g e t h e C o n f i g u r a t i o n F i l e t o M e e t t h e A p p l i c a t i o n Refer to the FieldServer Configuration Manual in conjunction with the Driver supplements for information on configuring the QuickServer.
  • Page 15: Load The Updated Configuration File

    Once download is complete, click the System Restart Button (or simply cycle power to the QuickServer) to put the new file into operation. Note that it is possible to do multiple downloads to the QuickServer before resetting it. ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 16: Test And Commission The Quickserver

    PS-GUI click on View, Connections to see the number of messages on each protocol. For troubleshooting assistance refer to Appendix B, or contact ProSoft technology Technical Support www.prosoft-technology.com/Support/ ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 17: Appendix A Useful Features

    To configure DIP switches B0-B3 to adjust the baud rate, the dynamic parameters field needs to be added to the configuration file. Dynamic_Parameters Function , Data_Array_Name , Data_Array_Offset , Descriptor_Name Baud_Rate , DA_BAUD , P1 ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 18 The S0 - S3 DIP switch selection is read directly into a Data Array. This Data Array value can be used for customized operations such as config file selection which allows a FieldServer to be loaded with several configurations / profiles that are selected based on a Data Array value.
  • Page 19: Appendix B Troubleshooting Tips

    FST_Diag program. Take a log (See ENote0058 in the folder called Library on the USB Flash Drive). Send this log together with a detailed description of the problem to support@fieldserver.com for evaluation. Note that while all necessary documentation is shipped with the FieldServer on the USB flash drive, these documents are constantly being updated.
  • Page 20: Appendix C Limited 2 Year Warranty

    In all cases FieldServer Technology’s responsibility and liability under this warranty shall be limited to the cost of the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this warranty provision and compliance with such instruction shall be a condition of this warranty.
  • Page 21: Appendix D Reference

    The ERR LED will go on solid 15 seconds after power up. It will turn off after 5 seconds. A steady red light will indicate there is a system error on the FieldServer. If this occurs, immediately report the related “system error”...
  • Page 22: Appendix D.2. Ps-Qs-1011/1510-Xxxx Led's

    PS-QS-1011-XXXX. If this occurs, immediately (LED1) report the related “system error” shown in the error screen of the FS_GUI interface to FieldServer Technologies for evaluation. The COMM ERR LED will flash once on power up and flash once 15 seconds after power up. A COMM ERR steady red light will indicate a communication error has occurred.
  • Page 23: Appendix D.3. Quickserver Fs-Qs-101X Dcc

    Be suited to the expected operating temperature range. Meet the current and voltage rating for the QuickServer/Net Furthermore, the interconnecting power cable shall: Be of length not exceeding 3.05m (118.3”) ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 24: Appendix D.5. Address Dip Switch Settings

    Restricted Access Area requiring a key or a special tool to gain access This device must not be connected to a LAN segment with outdoor wiring. Appendix D.5. Address DIP Switch Settings Address ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 25 QuickServer Start-up Guide Page 25 of 30 Address ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 26 QuickServer Start-up Guide Page 26 of 30 Address ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 27 QuickServer Start-up Guide Page 27 of 30 Address ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 28 QuickServer Start-up Guide Page 28 of 30 Address ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 29 QuickServer Start-up Guide Page 29 of 30 Address ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...
  • Page 30: Appendix D.6. Baud Dip Switch Settings

    Appendix D.6. Baud DIP Switch Settings Baud Auto 1200 2400 4800 9600 19200 20833 28800 38400 57600 76800 115200 4 Auto-baud is only supported for BACnet MS/TP ProSoft Technology, Inc. is a provider of FieldServer QuickServers. For Technical Support call +1 661.716.5100...