Connect to Line Power
The PDS-150e ships with the device's line, neutral, and ground wires connected
to the terminal block. You connect power to the device's flying leads by using the
included push wire connectors.
1. Install the included cable strain relief connector in one of the device's .88 in (22
mm) openings. If necessary, use conduit as required by local electrical codes.
2. Run the mains voltage power cable through the opening. Pull at least 6 in (152
mm) of wire into the housing.
3. Strip at least .38 in (10 mm) of insulation from the wires. Join the mains line wire
with the flying leads using the included push wire connectors.
4. If you need to assign DMX addresses your fixtures, or configure the PDS-150e
over an Ethernet network, follow the steps in the Addressing and Configuration
Guide prior to closing the device. Otherwise, secure the wire connections inside
the housing, put the cover over the device, and use eight of the included screws
and washers to close and secure the device's cover.
10
PDS-150e
Product Guide
Refer to your local electrical code for
E
requirements for proper connection to line
voltage.
.38 in
10 mm