Indoor Fan Motor Control - Toshiba RAS-10SKVR-E2 Service Manual

Air conditioner split type
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ ˚C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
(Table 1) Indoor fan air flow rate
Fan speed
COOL HEAT DRY
level
WF
UH
WE
WD
UH
M+
WC
H
WB
M+
M+
WA
W9
M
L+
W8
W7
L+
W6
L
W5
L-
UL
W4
UL
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WB)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4
*4 : Fan speed = (M + –L) x 2/4 + L
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W6)
from M+ and L)
Fan speed
(rpm)
1210
H
1210
1170
UH
1120
H
1040
M+
1000
M
960
L
870
L-
L+
850
760
L
760
L-
700
UL
SUL
650
500
500
(Fig. 1)
Fan speed
W6
(L + M) / 2
W9
(M + H) / 2
WC
(Fig. 2)
Air flow rate
(m3/h)
571
571
546
515
465
440
415
359
347
291
291
253
222
129
129
26
FILE NO. SVM-10029
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.