Installation Of The Burner - Desa BG SERIES Operating Instructions Manual

Cabinet warm air heater for oil burner
Table of Contents

Advertisement

For
installing
the
burner,
connections and carrying out the necessary adjustments,
refer to the instruction manual supplied with the burner.
We suggest that the fuel supply lines be built according to
the figures here beside.
For oil versions an adequate filter must be provided
in the fuel suction line.
BURNER COUPLING TABLE
The burners that can be used for best heater performance are the following:
RIELLO Oil Burners:
Type
Burner
Model
1
REG 5
2
R40G10
RG2
3
R40G10
RG2
4
R40G10
All Parts available from
RG2
5
R40 G20
RG 4S
www.sparesgiant.com
6
RL 28 tc
RL 28/1 tc
RG 5 S
01772 329 565
7
RL 38 tc
RL 34/1 MZ tc
BURNER ADJUSTMENT
Only qualified personnel can fit and adjust the burner, holding strictly to the instructions in the Burner Manual.
NB:
The adjustment of combustion air varies according to the characteristics of the chimney, and is done by acting on
the specific damper according to the instructions in the Burner Manual.

INSTALLATION OF THE BURNER

making
the
electrical
ADJUSTMENTS
Burner
Nozzle 60°W
Code
3772200
3452021
3737700
3452021
3737700
3452021
3737700
3452731
3739600
3473207
3472003
3739900
3474107
3470100
19
Nozzle Code
(G.P.H.)
n°1x1,00
1825027
n°1x1,50
1825037
n°1x1,50
1825028
n°1x1,75
1825037
n°1x1,75
1825033
n°1x2,00
1825037
n°1x2,00
1825022
n°1x3,50
1825026
n°1x3,50
1825024
n°2x2,25
1825023
n°2x2,25
1825023
n°2x2,25
1825023
n°2x3,50
1825024
n°2x3,50
1825024
Electric
supply
230V 50Hz~
230V 50Hz~
230V 50Hz~
230V 50Hz~
230V 50Hz~
230V 50Hz~
230V 50Hz~

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bg 110Bg 190Bg 260Bg 390Bg 50Bg 70 ... Show all

Table of Contents