Super Digital Inverter
Single system, Twin system, Triple system
Indoor/outdoor
connecting wire
1
2
3
Cord clamp
Cord clamp
WARNING
Be sure to attach the provided clamp filter to the power supply wire in order to conform to EMC standards.
Power supply wire
Earth screw
L1
L2
L3
N
Cord clamp
Clamp filter
(accessory)
Cord clamp
Stripping length power cord and connecting wire
10
Earth screw
40
(mm)
Connecting wire
24
1 2 3
L1 L2 L3 N
10
10
50
40
Earth line
Power supply wire
10
50
Earth line
24-EN