Rx550 Technical Specification
Power Requirements
Max Load
Receiver Current Draw
Fuses
Outputs
Facilities
Gain
Telemetry Signal
Auto Iris Output
Video Input
Video Output
Lens Drive
Presets
Other Outputs
Additional Information
Options
Boxed Dimensions
Weight
Rx450AC Rx550DC MK3 Installation Manual - V19 30Sep05.doc
230Vac or (110Vac or 24Vac as factory fitted option)
5A @ 230V
(1150 W)
Maximum of 100VA max
Auxiliary fuse
F2 5A T (20mm ceramic cartridge)
Linear 0-24Vdc output for pan & tilt motor drive
Switched 24Vdc output to drive motor brakes.
Lens drive adjustable between 5-12Vdc 150mA max
Total maximum of pan/tilt/lens and 24Vac auxiliary is 100VA.
Switched AC output to drive Wash/Wipe/Lights(1000W max)
LED readout for continual system status.
Programming menu with On Screen Display.
REMOTELY ADJUSTABLE
Video launch amplifier provided with cable length adjustment
12Vdc/500mA camera power provided.
Colour coded outlets – live, neutral, earth and low voltage.
2 or 4 wire Panasonic RS485
Returns to original setting 15 seconds after key release. Level
programmable from controller.
1v p-p 75Ω terminated input via BNC socket.
1v to 4v p-p 75Ω impedance via BNC socket.
REMOTELY ADJUSTABLE
Adjustable via menu between 6 – 12Vdc. Inching speed selectable via
menu between 0 – 12Vdc. 1 second inching built in. Provides drive for
Zoom & Focus. Each lens drive carries red and green LEDs to indicate
direction and drive voltage.
Inputs are provided for pan, tilt, zoom & focus preset feedback pots.
These are 10 bit resolution. Up to 64 full-scene presets can be stored
within the receiver, i.e. pan, tilt, zoom, focus for each preset.
RS485 Serial port available to drive advance features on selected
cameras.
Software Random Pan
Sequential preset patrol. The preset dwell is programmable individually.
Datum - return to preset 1, start preset patrol or random pan after menu
programmable duration of inactivity.
Iris output - either direct drive for 3 motor lens or Autoiris override voltage
for Seiko/Cosmicar lenses etc.
8 alarm inputs, volts free normally closed contacts. A single opening volts
free contact sums the alarms either immediately or as the preset is
approached. If a video transmission system is activated with the alarm
output, then setting the alarm to delayed prevents unwanted frames being
transmitted.
24Vac/230Vac auxiliary outputs are link selectable with link J3
Width: 380mm, Length: 190mm, Height: 130mm
3.43kg