Page 1
DUAL RELAY DIGITAL ACCESS CONTROL READER KEYPAD WEATHERPROOF HAA2890 Programming & Installation Manual FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS...
TABLE OF CONTENTS ..................4 INTRODUCTION .
Page 3
VOOR VERPAKKINGEN At the end of its life cycle, dispose of this product in accordance with local and national disposal regulations. Read the manual thoroughly before bringing this device into service Ontdoe u, op het einde van zijn levensduur, van dit product volgens de plaatselijke en nationale regelgeving inzake verwijdering.
The HAA2890 is a weatherproof, self-contained, mullion mount compact keypad. It combines the functions of digital keypad and proximity EM card reader in one unit. The HAA2890 has been designed to work independently as a stand alone keypad or works together with an optional “APO controller” to form a high security split-decoded keypad system.
SPECIFICATIONS Operating Voltage: 12V DC Nominal; 11-15V DC Operating Current: 60mA (quiescent) to 95mA (two relays active) Operation Temperature: -20 C to +70 C Environmental Humidity: 5-95% relative humidity non-condensing Working Environment & Ingress Protection: Indoor or Outdoor, IP-55 Weatherproof Number of Users: 1,000 (PINs and/or Cards) Proximity Card:...
CONNECTION HARNESS THE WIRE HARNESS 1 - 2 : TAMPER N.C. (Tamper Switch Normally Closed Contact) A normally closed dry contact while the front cover is secured on the main box. It is open while the cover is separated from the box. Connect this N.C. terminal to the 24 hour protection zone of an alarm system if necessary. 3 - 4 : DOOR BELL (Output Relay Contact for Door Bell) It is a Normally Open (N.O.) relay dry contact with maximum rating of 24VDC/1Amp.
10 - 11 - 12 : OUTPUT 1 (Output Relay 1) 2 Amp relay dry contact controlled by the Group 1 user PINs or Cards for Output 1, recommended for door strike. Terminal 10 is Normally Closed (N.C.), terminal 12 is Normally Open (N.O.) and terminal 11 is the common point of the two contacts.
FEATURE PROGRAMMING & OPERATION INSTRUCTIONS SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE IMPORTANT NOTE: 1) DO NOT TURN OFF POWER while the keypad is in Programming Mode. Otherwise, it may cause data lost/error to the programmed features in the memory. 2) The keypad beeps after power up.
REFRESH THE SYSTEM WITH THE “REFRESHING CODE” --- 9 9 9 9 The system can be refreshed to clear all the old data stored and back to its ex-factory default values. IMPORTANT NOTE: Make sure that you really want to clear ALL the OLD data before entering of the Refreshing Code. The keypad will be back with its default values like a new unit.
KEYPAD PROGRAMMING MAKE SIMPLE – For General Users The HAA2890 has many functions for user’s selection. For those general users taking the keypad for door strike only, most of the features can be kept in their Default values. Only the User PINs / Cards and a private Master Code are necessary to program for the system.
Page 12
6) Record an “EM Card + Commom User Code” to Operate The Output 1 for Door Open 10 4 004 READ CARD (a) 10 = Programming Location for Output 1 (b) 4 = Programming option for EM Card + Common User Code (c) 004 = One of the 1,000 User IDs for the User PIN/Card from 000-999 (d) Read Card = Put the Card close to the card reader (e) # = Confirm the card is read, 2 beeps, the Common User Code goes to this User ID automatically...
FEATURE PROGRAMMING -- KEY IN AND STORE THE DESIRED VALUES The feature values can be set and stored into the system one by one with the desired Programming Locations. Programming can be made continuously and it is not necessary to be in sequence order. Just go to the desired programming location and key in the value for the desired feature.
Example: User Name Location Function Code User ID PIN/Code Card # Remark 1,000 RECORD A MASTER CODE (Location 01) LOCATION MASTER CODE VALIDATION 4 to 8 Digits MASTER CODE Master Code is the authorization code for setting the system to programming mode. It is NOT an User Code operating of the output relays.
OPERATION AND FUNCTIONS OF THE SUPER USER PIN 1) Operate Output 1 (Output Relay 1) The operation of the Super User PIN is just like a normal User PIN. Simply key-in the PIN with a specific output number for the Output. The Super User PIN can also be used to reset an operating output timer instantly. ---------- Output 1 Activates or Resets SUPER USER PIN 2) Inhibit The User PINs For Output 1...
RECORD-DELETE PINS OR CARDS FOR OUTPUT 1 (Location 10) Total of 1,000 User PINs and/or Cards are available for controlling of the output relay 1. The Private User PINs and Cards MUST be unique. Repeated PINs will be rejected. Secondary User PINs in the “EM Card + Secondary User PIN”...
EXAMPLES – PROGRAMMING AND OPERATION 1) Example 1 -- EM Card Only : i) Programming : 10 1 001 Read Card (a) The card is programmed for operating of the Output 1 (b) The operation is EM Card only (c) Take ID number 001 in Group 1 to store the card, which is one of the IDs in 000-999 (d) Put the card close to the reader to read it, one beep confirms the reading (e) Press # to store the “Card”...
Page 18
4) Example 4 -- EM Card + Common User PIN : i) Programming : 10 4 004 Read Card (a) The card is programmed for operating of the Output 1 (b) The operation is “EM Card + Common User PIN” (c) Take ID number 004 in Group 1 to store the card, which is one of the IDs in 000-999 (d) Put the card close to the reader.
VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40) The Visitor Codes are the temporary user codes for operating of the Output 1 (mainly for door strike in access control). They can be programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes will be cleared automatically after use if they are one time codes, or, when the allowed time expires.
CONFIGURATION OF THE OUTPUT MODES OF OUTPUT 1 (Location 51) The relay output of this keypad is programmable for Start/Stop or Timing modes. Apart from the door access control, alarm arm-disarm control, it is also an universal timer for automatic operator in industry with its 99,999 seconds (over 24 hours) programmable timer.
USER PIN ENTRY MODE – Auto or Manual (Location 70) LOCATION ENTRY MODES VALIDATION USER PIN ENTRY MODES Two modes 1 and 2 are available for User PIN entry options. The EM Card is always in Auto Entry Mode and is not affected by the selection here.
OUTPUT OPERATION ANNOUNCER (Location 72) LOCATION FUNCTION MODES VALIDATION OUTPUT OPERATION ANNOUNCER The announcer gives notification beep to the users and the visitors on the operation status of the outputs. There are two notification modes available for the selection. The notification is also OFF while the Pacifier Tone OFF mode in the Location 71 is selected.
INTELLIGENT EGRESS BUTTON – AN UNIQUE FEATURE OF A CONTEMPORARY KEYPAD Most of the keypads for access control are just for controlling of “Going In” from outside. It is not enough for today’s access control systems. In fact, controlling of “Going Out” is also very important in many public passage areas. They are not allowed to use locks or digital keypads for stopping of “Going Out”...
EGRESS DELAY AND WARNING (Location 90) LOCATION FUNCTION MODES DELAY TIME VALIDATION CONFIGURATIONS OF THE EGRESS WARNING AND ALARM Key in the number to enable 1, 2, 4 or 5 configurations described below: --- Momentary Contact Mode without Warning -- (Default) • Press the Button once.
Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep (a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10 seconds to release door, (d) Entry confirmation Example 3: Set Egress Button in Momentary contact without delay (This is the default setting) (a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly, (d) Entry confirmation CLOSE THE PROGRAMMING MODE...
THE OPERATION MODES (Location 94) Four operation modes are available for the selection. The codes are 0, 1, 2 and 3. LOCATION OPERATION MODE VALIDATION WIEGAND OUTPUT AT KEYPAD OPERATION MODE 0 --- Stand Alone Keypad Mode -- (Default) The system provides full functions to operate its outputs. 1 --- Card &...
OPERATOR CONTROLLER COMMON GROUND MAXIMUM 3 KEYPADS CAN BE HAA2890 IN SPLIT-DECODED OPERATION DK-2890 CONNECTED IN PARALLEL The User Manual of the DA-2800 provides the operation details of the system on decoding controller mode and independent operation mode. Please contact your local agent if purchase of the DA-2800 Controller is required.
PROGRAMMING SUMMARY CHART ENTRY LIMITS & CODE LOCATION CODE ENTRY FUNCTION OPTIONS FACTORY DEFAULT Master Code 4-8 Digits MASTER CODE Super User PIN 4-8 Digits SUPER USER PIN Common User PIN for O/P 1 4-8 Digits COMMON USER PIN 1 CODE 1 - MEDIA: 1---EM Card 2---Private User PIN...
Page 29
OPERATION MODES 0---Stand Alone Keypad-Valid Codes & Cards Only Mode = 0 1---Reader-All Codes & Cards Operation Mode OPERATION MODE 2---Master Keypad-Valid Codes Keypad Mode & Cards only 3---Slave Keypad-Valid Codes & Cards only SYSTEM CODES FUNCTION CODE ENTRY RESULTS Factor y Set Master Code for User to set system in programming Mode at the...
APPLICATION EXAMPLE BASIC WIRINGS OF A STAND ALONE DOOR LOCK THE WIRE HARNESS OUTPUT RELAY N.O. Output for Fail-secure Lock N.O. N.C. N.C. Output for Fail-safe Lock 12V DC AD-1312 ELECTRIC LOCK POWER AP-960 SUPPLY EGRESS N.O. BUTTON CATHODE 1N4004 MORE EGRESS BUTTONS CAN N.O.
APPLICATION HINTS FOR THE AUXILIARY TERMINALS (A) TAMPER N.C. The tamper switch is Normally Closed while the keypad is secured on box. It is open when the keypad cover is removed from the box. To prevent sabotage, connect GREY these terminals in series with a 24 hour N.C. protection zone of an alarm system if required.
Page 32
Velleman® • A rticles to be rep paired must be d delivered to you ur Velleman® d ealer, solidly pa acked (pre eferably in the o original packagi ing), and be com mpleted with th...
Need help?
Do you have a question about the HAA2890 and is the answer not in the manual?