Vitodens 222-F, B2TA 19 and 35 Technical Data
Overview of Electrical Connections, Models B2TA 19 and 35
Legend
1
Outdoor Temperature Sensor
2
Supply Temperature Sensor/Low Loss Header
3
Boiler Temperature Sensor
4
DHW Supply Temperature Sensor
5
DHW tank temperature sensor
11
Ionization Electrode
15
Flue Gas Temperature Sensor
20
No Function
[20]
Boiler Pump Connection (Internal)
21
No Function
[21]
DHW Pump Connection (Internal)
28/20
Heat Circuit A1 Pump Connection*
30
Diverting Valve Stepper Motor
35
Gas Valve
40
Power Supply
40A
Accessory Power Output
47
Fixed High Limit
[53]
Powered Accessory Connection
54
Ignition Transformer
96
Powered Accessory Connection
100
Fan Motor
100A Fan Motor Control
111
Not Used
145
KM BUS
Multi
Powered Accessory Connection
156A Switched Output F2
156B
Switched Output F1
DE1
Digital Input 1 (Dry Contact)
DE2
Digital Input 2 (Dry Contact)
DE3
Digital Input 3 (Dry Contact)
0-10V 0-10VDC Input
157
Fault Alarm
190
Gas Modulation Coil
* Only one function/connection may be assigned
to each connection.
Boiler Control
A
External Accessory Connection Board
B
Pump Connection Interface
C
Extention Module EA1
D
KM-BUS for External Devices
E
Electrical Junction Box
F
Field Wiring Connections
G
A1 Main Board
A2 Internal Power Supply Unit
A3 Optolink
A4 Burner Control Unit
A5 Programming Unit
A6 Coding Card
A7 Connection Adaptor
A8 LON Communication Module
S1 ON/OFF Switch
S2 Reset Button
X.. Electrical Interface
Wiring Diagram
(continued)
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 222-f b2ta 19Vitodens 222-f b2ta 35

Table of Contents