Download Print this page

Pearson 323 Owner's Manual page 34

Pearson yachts

Advertisement

1.
FATHOMETER: Please refer to manufacturer
2.
SPEEDOMETER: Please refer to manufacturer's literature provided.
3.
APPARENT WIND INDICATOR: Please refer to manufacturer's
literature provided.
4.
MASTHEAD & SPREADER LIGHTS: On/Off switches on switch panel.
5.
ELECTRICAL REFRIGERATION: Refer to manufacturer's literature for
complete operational details.
6.
PROPANE (LPG.) STOVE: Please refer to manufacturer's literature
before operating. Never use flame to check for leaks.
CAUTION
A.
Keep container valve closed when boat is unattended. Close it
immediately in any emergency.
B.
Be sure all appliance valves are closed before opening container
valve.
C.
Always apply lit match or other flame to burner before opening
burner valve.
D.
Close master valve at appliance whenever appliance is not in
use.
E.
Test system for leakage at least twice a month and after any
emergency in accordance with the following procedures.
Procedure 1: With appliance valves closed, the master shutoff valve
on the appliance open, and with container valve open, note pressure
on the gauge. Close container valve. If the pressure drops, locate
leakage by application of liquid detergent or soapy water solution at
all connections.
Procedure 2: As shown in diagram a leak detector is provided in the
line at the container compartment. See Manufacturer's instructions.
To locate leak proceed as indicated above.
(DIAGRAM OF PROPANE SYSTEM FOLLOWS) 7. SHORE POWER CONVERTER: Refer
to manufacturer's literature.
Pearson 323 Owners Manual (1978 model year)
PEARSON YACHTS
OWNER'S GUIDE AND PROTECTION PLAN
PEARSON-323
SECTION XVII: OPTIONAL EQUIPMENT
literature provided.
Page 34 of 38

Advertisement