8. Slide the cover forward, taking care that it is securely positioned on the cold plate.
9. Reassemble.

BEVERAGE SYSTEM

1. Remove faucet spouts, wash in mild detergent, rinse and replace.
2. Disconnect electrical power to the carbonator. Shut off the water supply and close the CO
to the carbonator.
3. Disconnect the syrup tanks from the system.
4. Energize the beverage faucets to purge the remaining soda in the system.
5. Use a clean 5 gallon tank for each of the following.
A.
Cleaning tank - fill with hot (120° - 140° ) potable water.
B.
Sanitation tank - fill with a chlorine sanitizing solution in the strength of 1/2 ounce of household
bleach (sodium hypochlorite) to 1 gallon of cold (ambient) potable water (200 PPM).
6. Repeat the following procedure on each of the units'syrup product lines:
A.
Connect the cleaning tank to the syrup line to be sanitized and to the CO
B.
Energize the beverage faucet until the liquid dispensed is free of any syrup.
C.
Disconnect the cleaning tank and hook-up the sanitizing tank to the syrup line and CO
D.
Energize the beverage faucet until the chlorine sanitizing solution is dispensed through the faucet.
Flush at least 2 cups of liquid to ensure that the sanitizing solution has filled the entire length of the
syrup lines.
E.
Disconnect the sanitizing tank. Hookup the product tank to the syrup line and to the CO
F.
Energize the faucet to flush the sanitizing solution from the syrup line and faucet. Continue to draw on
the faucet until only syrup is dispensed.
7. Repeat Step 2 in reverse order to turn on the carbonator. Dispense at least 1 cup of beverage from each
faucet. Check taste. Continue to flush if needed, to obtain a satisfactory tasting drink.