7. INITIAL SETTING OF ADJUSTMENT VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile
memory to the initial setting value. However the results of the tempera-
ture compensation offset adjustment will not change to the initial setting
value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to "4. Precautions for Adjustments"
and execute the initial setting before the adjustment as required.
Setting Procedure:
[
AMS
]
1. Turn the
l
L
(MD) knob to display "ADJ CLEAR"
(C28).
[YES]
2. Press the
button. "Complete!" will be displayed mo-
mentarily and initial setting will be executed, after which "ADJ
CLEAR" (C28) will be displayed.
8. RECORDING AND DISPLAYING THE IOP
INFORMATION
The Iop data can be recorded in the non-volatile memory. The Iop
value on the optical pick-up label and the Iop value after the ad-
justment will be recorded. Recording these data eliminates the need
to read the label on the optical pick-up.
Recording Procedure:
[
AMS
1. Turn the
l
L
[YES]
(C05), and press the
2. The display becomes "Ref=@@@.@" (@ is an arbitrary num-
ber) and the numbers which can be changed will blink.
3. Input the Iop value on the optical pick-up label.
To select the number : Turn the
To select the digit : Press the
[YES]
4. When the
button is pressed, the display becomes
"Measu=@@@.@" (@ is an arbitrary number).
5. As the adjustment results are recorded for the 4 value. Leave it
[YES]
as it is and press the
6. "Complete!!" will be displayed momentarily. The value will
be recorded in the non-volatile memory and the display will
become "Iop Write" (C05).
Display Procedure:
[
AMS
1. Turn the
l
L
[YES]
(C26), and press the
2. "@@.@/##.#" is displayed and the recorded contents are dis-
played.
@@.@ indicates the Iop value on the optical pick-up label.
##.# indicates the Iop value after adjustment
[
AMS
3. To end, press the
l
button to display "Iop Read" (C26).
40
]
(MD) knob to display "Iop Write"
button.
[
AMS
]
(MD) knob.
l
L
[
AMS
]
(MD) knob
l
L
button.
]
(MD) knob to display "Iop Read"
button.
]
[MENU/NO]
L
(MD) button or
9. TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22 ˚C
to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Adjusting Procedure:
[
AMS
1. Turn the
l
L
ADJUST" (C03).
[YES]
2. Press the
button to select the "TEMP ADJUST" mode.
3. "TEMP =
[OK" and the current temperature data will be
displayed.
4. To save the data, press the
When not saving the data, press the
[YES]
5. When the
button is pressed, "TEMP =
be displayed and turned back to "TEMP ADJUST" (C03)
[MENU/NO]
display then. When the
ADJUST" (C03) will be displayed immediately.
Specified Value:
The "TEMP =
" should be within "E0 - EF", "F0 - FF", "00 -
0F", "10 - 1F" and "20 - 2F".
10. LASER POWER ADJUSTMENT
Check the Iop value of the optical pick-up before adjustments.
(Refer to 8. Recording and Displaying Iop Information)
Connection:
Optical pick-up
objective lens
BD (MD) board
CN105 pin 1 (I +3 V)
CN105 pin 2 (IOP)
Adjusting Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
button or
(MD) button to move the optical pick-up)
M
Connect the digital voltmeter to CN105 pin 1 (I+3V) and
CN105pin 2 (IOP) on the BD (MD) board.
[
AMS
2. Turn the
l
L
ADJUST" (C04).
(Laser power : For adjustment)
[YES]
3. Press the
button once to display "LD 0.9 mW $
[
AMS
4. Turn the
l
L
the laser power meter becomes 0.85 to 0.91 mW. Press the
[YES]
button after setting the range knob of the laser power
meter, and save the adjustment results. ("LD SAVE $
be displayed for a moment)
5. Then "LD 8.4 mW $
" will be displayed.
]
(MD) knob to display "TEMP
[YES]
button.
[MENU/NO]
button.
SAVE" will
button is pressed, "TEMP
laser
power meter
digital voltmeter
+
(MD)
m
]
(MD) knob to display "LDPWR
]
(MD) knob so that the reading of
" will
".