A. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
6-11/16 in.
(169 mm)
3-15/16 in.
(101 mm)
8 in.
(203 mm)
14-7/16 in.
367 mm
Figure 13.2 SLP vent components
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. G • 9/14
8 in.
(203 mm)
SLP-TRAP
Horizontal Termination Cap
3-13/16 in.
(97 mm)
SL-2DVP
Adapter
14-7/16 in.
367 mm
SLP-WT-BK
Wall Thimble-Black
Heat
Shield
Term Cap
Max
Effective
Length
3-15/16 in.
(101 mm)
5-1/16 in.
(128 mm)
2-5/16 in.
59 mm
Minimum
Effective Length
Effective Length
3-1/8 in.
Trap1
79 mm
5-1/4 in.
Trap2
133 mm
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
Maximum
4-3/4 in.
121 mm
9-1/4 in.
235 mm
61