Hide thumbs Also See for PUHZ-FRP71VHA:

Advertisement

Quick Links

Air-Conditioner
PUHZ-FRP71VHA

INSTALLATION MANUAL

For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the outdoor unit. English is original. The other languages versions are translation of the original.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation der Außenanlage das vorliegende Handbuch und die Installationsanleitung
der Innenanlage gründlich durchlesen. Das Original ist in Englisch. Die anderen Sprachversionen sind vom Original übersetzt.
MANUEL D'INSTALLATION
Avant d'installer l'appareil extérieur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil intérieur pour une
utilisation sûre et correcte. L'anglais est l'original. Les versions fournies dans d'autres langues sont des traductions de l'original.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het installeren
van het buitenapparaat begint. Het Engels is het origineel. De andere taalversies zijn vertalingen van het origineel.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la
unidad exterior. El idioma original del documento es el inglés. Las versiones en los demás idiomas son traducciones del original.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d'installazione dell'unità interna prima di installare
l'unità esterna. Il testo originale è redatto in lingua Inglese. Le altre versioni linguistiche rappresentano traduzioni dell'originale.
την εξωτερική μονάδα. Η γλώσσα του πρωτοτύπου είναι η αγγλική. Οι εκδόσεις άλλων γλωσσών είναι μεταφράσεις του πρωτοτύπου.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade interior antes de instalar
o aparelho de unidade exterior. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du
installerer udendørsenheden. Engelsk er originalen. De andre sprogversioner er oversættelser af originalen.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan utomhusenhet installeras så att den används
på ett säkert och korrekt sätt. Engelska är originalspråket. De övriga språkversionerna är översättningar av originalet.
Emniyetli ve doğru kullanım için, dış üniteyi monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu tamamıyla
okuyun. Aslı İngilizce'dir. Diğer dillerdeki sürümler aslının çevirisidir.
INSTALLASJONSHÅNDBOK
For å sikre trygg og riktig bruk skal denne håndboken samt installasjonshåndboken for innendørsenheten leses grundig
igjennom før enheten installeres. Engelsk er originalspråket. De andre språkversjonene er oversettelser av originalen.
ASENNUSOPAS
Turvallisen ja asianmukaisen käytön varmistamiseksi lue tämä opas sekä sisäyksikön asennusopas huolellisesti
ennen yksikön asentamista. Alkuperäiskieli on englanti. Muut kieliversiot ovat alkuperäisen käännöksiä.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
FOR MONTØR
ASENTAJALLE
English
Deutsch
Français
Nederlands
Español
Italiano
Eλληνικά
Português
Dansk
Svenska
Türkçe
Norsk
Suomi

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PUHZ-FRP71VHA

  • Page 1: Installation Manual

    Air-Conditioner PUHZ-FRP71VHA INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the outdoor unit. English is original. The other languages versions are translation of the original. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE...
  • Page 2: Table Of Contents

    This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
  • Page 3: Installation Location

    1. Safety precautions 1.2. Before installation (relocation) Caution: • Be extremely careful when transporting or installing the units. Two or • The base and attachments of the outdoor unit must be periodically more persons are needed to handle the unit, as it weighs 20 kg or more. checked for looseness, cracks or other damage.
  • Page 4: Installing The Outdoor Unit

    2. Installation location 2.2. Choosing the outdoor unit installation location • Avoid locations exposed to direct sunlight or other sources of heat. • Select a location from which noise emitted by the unit will not inconvenience neighbors. • Select a location permitting easy wiring and pipe access to the power source and indoor unit.
  • Page 5: Installing The Outdoor Unit

    3. Installing the outdoor unit (mm) • Be sure to install the unit in a sturdy, level surface to prevent rattling noises dur- ing operation. (Fig. 3-1) <Foundation specifi cations> Foundation bolt M10 (3/8") Thickness of concrete 120 mm Length of bolt 70 mm Weight-bearing capacity 320 kg...
  • Page 6 4. Installing the refrigerant piping 4.2. Connecting pipes (Fig. 4-1) • When commercially available copper pipes are used, wrap liquid and gas pipes with commercially available insulation materials (heat-resistant to 100 °C or more, thickness of 12 mm or more). •...
  • Page 7 4. Installing the refrigerant piping 4.4. Refrigerant pipe airtight testing method (Fig. 4-4) Stop valve (1) Connect the testing tools. • Make sure the stop valves are closed and do not open them. • Add pressure to the refrigerant lines through the service port A of the liquid stop valve.
  • Page 8: Drainage Piping Work

    4. Installing the refrigerant piping 4.7. Precautions when reusing existing R22 refrigerant pipes • Refer to the fl owchart below to determine if the existing pipes can be used and if it is necessary to use a fi lter dryer. •...
  • Page 9: Electrical Work

    6. Electrical work 6.1. Outdoor unit (Fig. 6-1, Fig. 6-2) 1 Remove the service panel. 2 Wire the cables referring to the Fig. 6-1 and the Fig. 6-2. A Indoor unit Fig. 6-2 B Outdoor unit C Remote controller F Terminal block for power (L, N, ) and Indoor-Outdoor connection (S1, S2, S3) D Main switch (Breaker) For Power...
  • Page 10: Test Run On Air Conditioner Side

    7. Test run on air conditioner side 7.1. Before test run • The insulation resistance drops due to accumulation of refrigerant in the com- pressor. The resistance will rise above 1 M" after the compressor is warmed ► After completing installation and the wiring and piping of the indoor and up for four hours.
  • Page 11 8. Special functions 8.3. Refrigerant collecting (pump down) (Fig. 8-3) The refrigerant collecting function is available by performing the following procedure. 1 Close the 2 liquid stop valves and the cylinder/hydro unit side gas valve. Only the indoor unit side gas valve remains open. 2 Connect the 2 gas stop valve service ports with a hose.
  • Page 12 EG-DEKLARATION OM ÖVERENSSTÄMMELSE EY-VAATIMUSTENMUKAISUUDEN VAKUUTUS EG-CONFORMITEITSVERKLARING MITSUBISHI ELECTRIC CORPORATION, SHIZUOKA WORKS 18-1, OSHIKA 3-CHOME, SURUGA-KU, SHIZUOKA-CITY 422-8528, JAPAN hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 13 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original. CAUTION CUIDADO • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
  • Page 14 Fig. 2-6 Fig. 2-7 Fig. 2-8 1000 Fig. 2-9 Fig. 2-10 Fig. 2-11 Fig. 2-12 Fig. 2-13 Fig. 2-14 Fig. 2-15 Fig. 2-16 Fig. 2-17 Fig. 2-18...
  • Page 15 • Energy-related Products Directive 2009/125/ EC • RoHs Directive 2011/65/ EU HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. RG79D791H02 Printed in JAPAN HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K.

Table of Contents