Safety Thermostat; Water Temperature Not Right; Warm Water Temperature Too High; Probability Of A Water Leakage - A.O. Smith EES 30 User Instruction

United kingdom / ireland
Table of Contents

Advertisement

2.5

Safety thermostat

Every heater has got a number of safety thermostats
interrupting the elcetric circuit, at high water temperatures
(95°C). These safety thermostats cannot be reset
but after a drecrease of the temperature by 20°C.
Subsequently, the regulating thermostat will be checked:
if it has been adjusted at a high temperature, the
thermostat will probably be broken and must be replaced.
2.6

Water temperature not right

I. Check the adjustment of the regulating thermostat.
2. Check whether there are leakage's and/or open taps.
3. Check whether the wiring is still correctly connected.
4. It's possible that the consumption of hot water is
higher than it had been calculated, originally.
5. Inspect wheter the cold water inlet pipe has got the
right position.

2.6.1 Warm water temperature too high

Check whether the regulating thermostat is set too high.
2.7

Probability of a water leakage

I. Check whether the drain tap is completely shut.
2. Check whether the water connections are waterproof.
2.8

Important advises

The heater must NEVER be put into operation,
with the cold water supply turned off.
The heater must not be under pressure nor
voltage, in the course of a maintenance.