16.2. Sensible Capacity Chart

CS-E7GKEW CU-E7GKE
230V
Indoor wet
bulb temp.
TC
17.0°C
2.03
19.0°C
19.5°C
2.23
22.0°C
2.43
CS-E9GKEW CU-E9GKE
230V
Indoor wet
bulb temp.
TC
17.0°C
2.58
19.0°C
19.5°C
2.83
22.0°C
3.09
CS-E12GKEW CU-E12GKE
230V
Indoor wet
bulb temp.
TC
17.0°C
3.47
19.0°C
19.5°C
3.81
22.0°C
4.15
TC
-
Total Cooling Capacity (kW)
SHC
-
Sensible Heat Capacity (kW)
IP
-
Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C
30
SHC
IP
TC
SHC
1.54
0.44
1.90
1.48
2.05
1.61
0.45
2.09
1.55
1.67
0.46
2.27
1.61
30
SHC
IP
TC
SHC
1.96
0.54
2.41
1.88
2.60
2.05
0.55
2.65
1.97
2.12
0.56
2.88
2.04
30
SHC
IP
TC
SHC
2.63
0.87
3.24
2.52
3.50
2.76
0.89
3.56
2.65
2.86
0.90
3.88
2.75
Outdoor Temp. (°C)
35
40
IP
TC
SHC
0.47
1.77
1.42
0.48
0.48
1.94
1.49
0.49
2.12
1.55
Outdoor Temp. (°C)
35
40
IP
TC
SHC
0.58
2.24
1.80
0.59
0.59
2.46
1.89
0.60
2.68
1.97
Outdoor Temp. (°C)
35
40
IP
TC
SHC
0.94
3.02
2.43
0.95
0.95
3.31
2.55
0.97
3.61
2.65
67
46
IP
TC
SHC
0.51
1.61
1.35
0.55
0.52
1.77
1.42
0.56
0.52
1.92
1.48
0.57
46
IP
TC
SHC
0.62
2.04
1.71
0.67
0.63
2.24
1.80
0.68
0.64
2.44
1.88
0.70
46
IP
TC
SHC
1.00
2.74
2.30
1.08
1.02
3.01
2.43
1.10
1.04
3.28
2.53
1.12