Disassembly Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Cabinet Doors

Door Gaskets

1. Grasp gasket in upper corners and pull gasket out of
dart retainer.
2. When reinstalling door gaskets start at corners
pushing dart edge into retainer and make sure to
seat gasket flush to door.

Dispenser Facade (some models)

1. Remove drip tray by pulling it straight out from door.
2. Remove two hex screws at the bottom of facade that
were hidden by drip tray.
3. Push down on facade to release retainer clips.
4. Remove facade and disconnect ten pin connector from
control board.
5. Reverse procedure to reassemble.

Dispenser Ice Chute Door (some models)

1. Remove dispenser facade (see dispenser facade
removal)
2. Remove ice chute assembly (see D/C solenoid
removal)
3. After ice chute assembly is removed unsnap ice
chute dispenser door from assembly.
4. Retain spring if good, replace if bad.
5. Remove rubber seal from door and replace if bad.
6. Reverse procedure to reassemble.
I
C
CE
HUTE
I
C
D
CE
HUTE
OOR
D
OOR
H
INGE
I
C
CE
HUTE
A
SSEMBLY
DC S
L
S
IGHT
OCKET

Dispenser Light Socket (some models)

1. Remove dispenser facade (see dispenser facade
removal)
2. Remove light bulb.
3. Disconnect wires to socket assembly.
4. Squeeze tabs located by terminals to release socket.
5. Reverse procedure to reassemble.
©2005 Maytag Services
!
WARNING
OLENOID
16025628

Dispenser D/C Solenoid (some models)

1. Remove dispenser facade (see dispenser facade
removal)
2. Remove dispenser water tube clip.
3. Remove water tube from assembly collar.
4. Remove wires from dispenser light socket.
5. Disconnect ground wire from solenoid assembly.
6. Disconnect wires from D/C solenoid.
7. Remove screws holding D/C solenoid and ice chute
assembly.
8. Remove complete assembly.
9. Rotate to backside and remove screws holding D/C
solenoid to ice chute assembly.
10.Lift ice chute door to release plunger from retainer.
11. Slide D/C solenoid out of the side of ice chute
assembly.
12. Reverse procedure to reassemble.
Dispenser Water Tube (some models)
1. Remove toe grill and left hinge cap to expose
dispenser water line coupler.
2. Disconnect water line coupler.
3. Remove compression nut and sleeve from door side
of coupler.
4. Remove dispenser facade (see dispenser facade
removal).
5. Pull water tube up from conduit in cavity to remove
water tube.
6. Reverse procedure to reassemble.