Set Level; Set Lvldelay; Set Name - RFI PA516 Series User Manual

Am rf power amplifier
Table of Contents

Advertisement

PA516 Series User's Manual

SET LEVEL

Purpose:
Syntax:
Example:
Response:
Comment

SET LVLDELAY

Purpose:
Syntax:
Example:
Response:
Comment

SET NAME

Purpose:
Syntax:
Example:
Response:
Comment
Used to set the reference output power level.
set level
Type:
SET
LEVEL
Current output power = 41.3dBm.
This level will become the nominal level for alarm purposes.
Are you sure? (YES/NO) >
Type:
YES
If the output power level deviates by more than +/-6dB from the level set with this command, a
Major alarm condition will be activated.
If the reference output power level has not yet been configured, no output power level alarms will
be generated.
Sets the delay period before a level alarm is raised.
set lvldelay {1..99}
Type:
SET
LVLDELAY
Delay to Level Alarm = 15 Sec
The output power level needs to be more than 6dB above or below the Reference level for this period
of time before an alarm is signalled.
Used to designate the name of the site.
set name {name}
Type:
SET
NAME
SITE-1234A
>
The name can be up to 16 characters long. Any of the visible characters from a PC keyboard may
be used, except for a space. When other commands such as SHOW ID and SHOW STATUS are
used, they will include the site name.
Asia Pacific | EMEA | Americas