Dometic RM7030 Installation & Operating Instructions Manual page 5

Automatic energy selector refrigerator for lp/gas and electric operation
Hide thumbs Also See for RM7030:
Table of Contents

Advertisement

The gas supply system must incorporate a pressure regu-
lator to maintain a supply pressure of not more than 13-1/2
inches water column, (static) no load.
LP GAS
CYLINDER
When testing the gas supply system at test pressures in
excess of 1/2 psig, the refrigerator and its individual shutoff
valve must be disconnected from the gas supply piping
system.
When testing the gas supply system at pressures less than
or equal to 1/2 psig, the appliance must be isolated from the
gas supply piping by closing its individual manual shutoff
valve.
In case detailed instructions on the installation and connec-
tion to the gas supply are required, contact your dealer or
distributor.
9. TESTING
LP
SHUTOFF
The gas safety shutoff must be tested after the refrigerator
is connected to LP gas supply.
To test the gas safety shutoff, proceed as follows:
A. Start the refrigerator according to the instructions, and
switch to gas mode. See " Section C. Operation Instruc-
tions ."
B. Check that the gas flame is lit and the gas mode indicator
lamp (C) is on. See FIG. 9.
C. Close the manual shutoff valve at the back of the
refrigerator. (See FIG. 6)
D. Wait for one minute. The check indicator lamp (D) should
now be lit and the gas mode indicator lamp should be off.
FIG. 6
Heaters
Protection
Cover
Flue Baffle
PRESSURE
REGULATOR
T O
REFRIGERATOR
GAS
SAFETY
Burner Jet
12 Volt
Terminal
Manual Gas
Block
Shutoff V alve
Power Module
Cover
E. Remove cover (see FIG. 6) and open the manual gas
valve. Apply a noncorrosive commercial bubble solution
to burner jet (see FIG. 6).
F. No bubbles should appear at the opening of the burner jet.
The presence of bubbles indicates a defective gas safety
shutoff, and service is required.
G. If no bubbles were present at the burner jet, the gas
safety valve is working properly. Rinse jet thoroughly
with fresh water before proceeding. Be careful not to
damage burner jet. Replace cover and turn the main
switch OFF and back ON. (See " Section C. Operation
Instructions, Item 2. Control Panel "). Normal operation of
the burner should return. Allow the burner to operate for
a minimum of 5 minutes.
DO NOT use a flame to check for leaks.
10. 120 VOLT AC ELECTRICAL
CONNECTION
The refrigerator is equipped with a three-prong (grounded)
plug for protection against shock hazards, and should be
plugged directly into a properly grounded three-prong recep-
tacle. DO NOT cut or remove the grounding prong from this
Flexible Cord
5
WARNING
Drain W ater Hose

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents